Custom fixed PDOs available upon request. PDO1 must be 5V. PDO2 through PDO7 may be set to any custom voltage from 3.3V to 21V, with a step size of 100mV.
Note 2:
In critical applications, the use of a non-authorized USB PD power adapter may pose a substantial risk. The power adapter's identity may be checked and validated prior to PD contract negotiation by using USB PD Vendor Defined Messages (VDMs). Please see our article Product Security and Risk Mitigation for USB Power Delivery (PD) Based Systems for additional information.
Input
Input Voltage:
Specified: 85-264VAC, Nameplate: 100-240VAC 100% rated load current for 85-264VAC 100% rated load current for 110-370VDC
Input Frequency:
Specified: 47-63Hz, Nameplate: 50-60Hz
No Load Input Power:
< 150mW @ 230VAC (EU CoC Tier 2 compliant)
Inrush Current:
60A @ 115VAC, 120A @ 230VAC typ. (at peak of AC line, cold start)
Efficiency:
DoE Efficiency Level VI and CoC Tier 2 compliant (tested according to DoE 10 CFR Part 430, Subpart B, Appendix Z)
Output
Turn-on Delay:
< 1 second @ 115VAC and full load
Output Regulation
± 4% max. (measured at the end of a 1m long output cord)
Line Regulation:
± 0.5% typ. (measured at the end of a 1m long output cord)
Ripple:
75mV max. (0 - 100% load, using a 47µF low-ESR electrolytic cap + 0.1µF ceramic cap, measured @ 20MHz BW, at the output connector)
4000VAC or 5656VDC from input to output 10mA, 1 minute
Output Leakage Current:
Class II "F1" (two-conductor input): NC: 100µA max. SFC: 150µA max.
Class II "F2" (functional earth (FE)): NC: 10µA max. SFC: 100µA max.
Class I (earthed output): NC: 5µA max. SFC: 100µA max.
Earth Leakage Current
300µA max. NC & SFC (N/A for 2-conductor input models)
Means of Protection:
2 x MOPP
Output Isolation Options:
-T2 suffix: Class II (two-conductor input) -T3 suffix: Class II (with functional earth (FE)) ~or~ Class I (earth wire connected directly to output negative)
IEC61000-4-5, 2KV differential, 4KV common-mode, Criterion A
Conducted RF Immunity:
IEC61000-4-6, 10VRMS, 80% 1KHz AM, Criterion A
Voltage Dip Immunity:
IEC61000-4-11, Criterion B/C
Enclosure
Housing:
High impact plastic, 94V0 polycarbonate, non-vented
Markings:
Adhesive backed label or laser engraving
Prevention of Unauthorized Use
USB Power Delivery:
In critical applications, the use of a non-authorized USB PD power adapter may pose a substantial risk to system safety or performance.
The power adapter's identity may be checked and validated prior to PD contract negotiation by use of USB PD Vendor Defined Messages (VDMs). The power adapter will respond to a USB PD “Discover Identity” VDM with 0x4754 in the “ProductID” field.
Additionally, a non-standard 15.1V PDO is included. Host systems may be designed to reject a power adapter which does not contain a 15.1V PDO.
Note 5:
These measures do not ensure a secure implementation, and are only suggested as a method of risk mitigation.
Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
CE Certification
CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Japan: Voluntary Control Council for Interference (VCCI)
RoHS
Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/