BL5000C21703S3PFT Battery Cylindrical Can null

BL5000C21703S3PFT
BL5000C21703S3PFT, , Battery Cylindrical Can, Battery Li-Ion, , Input Rating: , , Output Rating:  Watts, Power rating with convection cooling (W) , V in 0.1V increments, Approvals:BL5000C21703S3PFT, , Battery Cylindrical Can, Battery Li-Ion, , Input Rating: , , Output Rating: Watts, Power rating with convection cooling (W) , V in 0.1V increments, Approvals:
Information
Guidelines and cautions, Safety Notes, and Safety Precautions published on GlobTek’s website
Model NumberBL5000C21703S3PFT
Agency Documentshttp://www.globtek.info/certs/BL3500C1865001S1PCMK/
CE EC-Declaration for MedicalContact GlobTek for more information
CE EC-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for MedicalContact GlobTek for more information
UKCA-Declaration for Industrial/Commercial/ITEContact GlobTek for more information
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O3a00000OA61FEAT
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000OA61FEAT
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeBattery Cylindrical Can
TechnologyBattery Li-Ion
ChemistryLi-Ion
Cell Rated Capacity (mAh)5000
Cell Nominal Voltage3.6
Cell GeometryCylindrical
Cell Length
Cell Width
Cell Height
Cell Diameter
Rating Table
Model Number (Final ordering #/Part No to be defined)Voltage (V)Current (A)Power (W)RFQ
* (Final ordering #/Part No to be defined)
Specifications

General Pack Specifications

Description:Lithium-ion battery pack with SMBus-compatible battery management system (BMS)
Includes Built-In Charger?No
Includes Safety Protections?Yes
Includes Fuel Gauge?Yes, via SMBus
BMS Details:ICs: BQ40Z50 + BQ294702

PCB: 500-10011140(R)
Cell configurations for which this electrical specification applies:1s4p
2s2p, 2s3p, 2s4p
3s2p, 3s3p, 3s4p
4s2p, 4s3p, 4s4p
Nomenclature:The abbreviation (# 'p') is the "# of parallel strings" (i.e. the "Y" in XsYp)
The abbreviation (# 's') is the "# of series cells in each string" (i.e. the "X" in XsYp)

Cell Specifications

Cell P/N:LR2170
Nominal Cell Capacity:5000mAh [Per cell manufacturer spec, 4.2V - 2.5V discharge, 0.2C, 25°C]
Initial Internal Impedance per Cell:30mΩ (max.)
Cell Approvals:UL1642

Charge Specifications

Compatible Charging Method:Constant current (CC) + constant-voltage (CV)
SMBus Smart Charger Compatible (SBS)?Yes, pack suggests charging parameters based on measured pack temperature and SoC (SBS compatible chargers only)
CC Current: 
 2p3p4p
0°C to 5°C0.75A1.125A1.50A
5°C to 10°C1.50A2.25A3.00A
10°C to 45°C2.00A3.00A4.00A

[Maximum recommend values & SMBus ChargingCurrent() defaults]
CV Voltage: 
 1s2s3s4s
0°C to 5°C4.000V8.000V12.000V16.000V
5°C to 35°C4.125V8.250V12.375V16.500V
35°C to 45°C4.000V8.000V12.000V16.000V

[Maximum recommended value & SMBus ChargingVoltage() default]
Pre-Charge Current:When charging, if any cell's voltage is <3.00V, the charger should supply 0.075C [0.375A • (# 'p')] or less, until all cells are ≥3.00V
 
2p3p4p
0.75A1.125A1.50A

[Maximum recommend values & SMBus ChargingCurrent() defaults]
Charge-Termination Current:0.05C [0.250A • (# 'p')]

Discharge Specifications

Maximum Continuous Discharge Current:8.0A
Recommended Discharge Cutoff Voltage:3.0V • (# 's')
Usable Discharge Capacity (typ.):4500mAh • (# 'p') [4.125 - 2.8V discharge @ 0.2C]
4200mAh • (# 'p') [4.125 - 3.0V discharge @ 0.2C]
Cycle Life (typ.):750 cycles [≥ 70% of 1st cycle capacity, [4.125 - 2.8V, 0.2C charge / 0.2C discharge, 25°C]

Environmental

Ambient Temperature Range (in Charge):0°C to 45°C
Ambient Temperature Range (in Discharge):-20°C to 45°C
Humidity:0 - 85% RH
Atmospheric Pressure:86 - 106kPa
Storage:Maintain SoC between 30 - 50%

-20°C to 50°C
0 - 70% RH

Suggested maintenance charge intervals:
Every 3 months at -20°C to 25°C
Every 1 month at -20°C to 50°C
Handling:Please follow GlobTek, Inc. HANDLING AND SAFETY PRECAUTIONS FOR Li-Ion & Li-Polymer.


 

Recoverable Protection Parameters

Over-Voltage in Charge:Trip threshold = T
Recovery threshold = R
 1s2s3s4s
0°C to 5°C4.100V (T)
3.900V (R)
8.200V (T)
7.800V (R)
12.300V (T)
11.700V (R)
16.400V (T)
15.600V (R)
5°C to 35°C4.225V (T)
4.025V (R)
8.450V (T)
8.050V (R)
12.675V (T)
12.075V (R)
16.900V (T)
16.100V (R)
35°C to 45°C4.100V (T)
3.900V (R)
8.200V (T)
7.800V (R)
12.300V (T)
11.700V (R)
16.400V (T)
15.600V (R)

Trip delay: 2s
Under-Voltage in Discharge:Trip:        2.80V ± 0.05V (any cell)
Release: 3.10V ± 0.05V (any cell)
Trip delay: 2s (typ.)
Over-Current in Charge (typ.): 
LevelDelayTrip threshold
2p3p4p
16s2.67A4.00A5.32A
23s3.50A5.25A7.00A
Over-Current in Pre-Charge (typ.) 
2p3p4p
1.0A1.5A2.0A

Trip delay: 2s
Over-Current in Discharge (typ.): 
LevelDelayTrip threshold
2p3p4p
16s10.0A10.0A10.0A
23s12.0A12.0A12.0A
Over-Temperature in Charge (typ.):Trip: 45°C
Release: 40°C
[Cell surface temperature]
Under-Temperature in Charge (typ.):Trip: 0°C
Release: 5°C
[Cell surface temperature]
Over-Temperature in Discharge (typ.):Trip: 60°C
Release: 45°C
[Cell surface temperature]
Under-Temperature in Discharge (typ.):Trip: -20°C
Release: -15°C
[Cell surface temperature]

Non-Recoverable (Permanent Fail) Protection Parameters

Method of deactivation:SCP (Externally triggered fuse)
Permanent Over-Voltage in Charge:Trip: 4.275V ± 0.05V (any cell)
Trip delay: 5s (typ.)
Permanent Over-Voltage in Charge (Standalone backup IC):Trip: 4.300V ± 0.05V (any cell)
Trip delay: 6s (typ.)
Permanent Under-Voltage in Discharge (typ.):Trip: 2.200 ± 0.05V (any cell)
Trip delay: 5s
Permanent Over-Current in Charge  (typ.): 
2p3p4p
4.50A6.75A9.00A

Trip delay: 10s
Permanent Over-Current in Discharge (typ.):Trip: 14.0A
Trip delay: 5s
Permanent Cell Over-Temperature (typ.):Trip: 65°C
Trip delay: 10s
[Cell surface temperature]

Approvals & Regulatory

RoHS:Complies with 2011/65/EU + (EU)2015/863 and China SJ/T 11364-2014
CE:Complies with 2013/56/EU, including, but not limited to, EN61000-6-1:2007, EN61000-6-3:2007
Transportation:Designed to meet UN38.3
Safety:Designed to meet UL2054, IEC62133-2 (ed1.1)
 
Derating Curve
Qty (ea.)/Carton
Individual Box/Gift Box Size (mm)
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)TBD
Gross Weight (kg)90.0
Label Width (mm)null
Label Height (mm)null
Input Configuration
Description

Guidelines and cautions, Safety Notes, and Safety Precautions published on GlobTek’s website

http://en.globtek.com/safety-cautions.php

The purchaser of GlobTek battery pack products (Customer) agrees that they are a "Sophisticated user" who understands battery technology and that it is their sole responsibility to determine suitability of the product described for their application and to take precautions for protection against any hazards attendant to the handling and use of the product. GlobTek products are only designed for professional use and integration by companies into their products and may not be used by consumers directly. GlobTek provides batteries and battery packs as a component of an end system.

The acceptance of GlobTek specifications, the information on this page and use of the product(s) described in this or other GlobTek documents indicate that the product was qualified for use (tested and/or sample waiver signed), and the acceptance and binding of the customer to GlobTek terms and conditions, which supersede all other agreements, terms and conditions http://www.globtek.com/about/terms-and-conditions

Lithium Ion batteries are inherently dangerous. Continuous usage or charging without allowing the battery to discharge is a hazard.

FIRE HAZARD: This like all Li-Ion battery packs must be regularly discharged and charged. it is not recommended to be kept on permanent fullcharge and in a full state of charge.

Request Info