GTM41061-25VV-FW PCB Mounted/DIP Medical Power Supply
GTM41061-25VV-FW | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | GTM41061-25VV-FW, Medical Power Supply, PCB Mounted/DIP, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 25 Watts, Power rating with convection cooling (W) , 5-30V in 0.1V increments, Approvals: CB, CE, cETLus, cETLus 60601.1, China RoHS, Double Insulation, IP21, Level V -115 (15V+), PSE, RoHS 2, S-Mark, VCCI, WEEE GTM41061-25VV-FW, Medical Power Supply, PCB Mounted/DIP, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 25 Watts, Power rating with convection cooling (W) , 5-30V in 0.1V increments, Approvals: CB, CE, cETLus, cETLus 60601.1, China RoHS, Double Insulation, IP21, Level V -115 (15V+), PSE, RoHS 2, S-Mark, VCCI, WEEE | ||||||||||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||||||||||
Model Number | GTM41061-25VV-FW | ||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM41061/ | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0Oa000000JBOT9EAP | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0Oa000000JBOT9EAP | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000JBOT9EAP | ||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000JBOT9EAP | ||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||
Type | PCB Mounted/DIP | ||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||||||||||||||||||||
Category | Medical Power Supply | ||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 0.6A | ||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 25 | ||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5-30 | ||||||||||||||||||||||||||||||||||||||||
Efficiency | See Approvals | ||||||||||||||||||||||||||||||||||||||||
Ingress Protection | N/A | ||||||||||||||||||||||||||||||||||||||||
Size (mm) | 84*56*38 | ||||||||||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 3. Output Regulation: +/- 5% measured at the output connector 4. Line Voltage Regulation: +/- 1% typical measures at full load 5. Output Ripple (Vp-p): 1% or 150 mV whichever is greater measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line 6. Turn-On/Turn-Off Overshoot: 5% maximum, 1mS typical recovery time for 25% step load 7. Turn-On Delay: 1 second typical 8. Hold-Up Time: 8mS typical @ nominal input voltage & full load 09. Inrush Current: 30A typical @ 115Vac input ; 60A typical @ 230Vac input 10. Switching Frequency: 66.5 KHz typical B) PROTECTION 1. Over-Voltage: Protected via zener diode across the output 2. Short Circuit: Electronically Protected, unit will recover upon removal of fault 3. Input Protection: Input dual-fusing (for both line and neutral) C) SAFETY 1. Dielectric Withstand Voltage: 5656 Vdc from primary to secondary 2. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition) 3. Means of Protection: 2 x MOPP (Means Of Patient Protection) 4. ESD: 8 kV Contact/15kV Air Discharge D) OTHER: 1. MTBF: 200,000 hours @ 25°C ambient temperature 2. Operating Temperature: 0°C to 40°C ambient temperature 3. Humidity: 0% to 93% relative humidity, passed 7 day humidity testing per IEC 60601-1 4. Storage Temperature: -10°C to 80°C E) ENCLOSURE 1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented 2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented 3. Size: 84.0* 56.0*37.9 mm +/-1.0 4. Green LED "ON" indicates output power "Available" | |||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 80 | ||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 117L*82W*L*59H | ||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 462 x 342 x 300 | ||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 15.2 | ||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 45.8 | ||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 40.5 | ||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||
Description | |||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||||||||||
|