USB Power Delivery Capabilities| Protocol supported: | USB Power Delivery (PD) 2.0/3.0 + PPS |
|---|
| Advertised Power Data Objects (PDOs/APDOs): | Standard option: 5V,, 9V, 12V,
|
|---|
| Note 1: | Custom fixed PDOs available upon request. PDO1 must be 5V. PDO2 through PDO7 may be set to any custom voltage from 5V to 12V |
|---|
| Note 2: | In critical applications, the use of a non-authorized USB PD power supply may pose a substantial risk. Power supply authorization may be implemented using USB PD Vendor Defined Messages (VDMs) to prevent system operation with non-authorized power sources. Please see our article Product Security and Risk Mitigation for USB Power Delivery (PD) Based Systems for additional information. |
|---|
Input| Input Voltage: | Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 85% rated load current for 85-264VAC 100% rated load current for 110-370VDC |
|---|
| Input Frequency: | Specified: 47-63Hz, Nameplate: 50-60Hz |
|---|
| No Load Input Power: | < 75mW @ 230VAC (EU CoC Tier 2 compliant) |
|---|
| Inrush Current: | < 30A @ 115VAC, < 60A @ 230VAC (cold start) |
|---|
| Efficiency: | DoE Efficiency Level VI and CoC Tier 2 compliant (tested according to DoE 10 CFR Part 430, Subpart B, Appendix Z) |
|---|
Output| Turn-on Delay: | < 1 second @ 115VAC and full load |
|---|
| Output Regulation | ± 4% max. (measured at the end of a 1m long output cord) |
|---|
| Line Regulation: | ± 0.5% typ. (measured at the end of a 1m long output cord) |
|---|
| Ripple: | 100mV max. (using a 47µF low-ESR electrolytic cap + 0.1µF ceramic cap, measured @ 20MHz BW, at the output connector) |
|---|
| Transient Response: | 5% max. deviation, 1ms max. recovery time (with 25% load step), |
|---|
| Hold-up Time: | 8ms min. (100VAC and full load) |
|---|
| Power Indicator: | Green LED |
|---|
Protections| Input Protection: | MOV transient suppressor, input line fusing |
|---|
| Over-Voltage Protection: | Level 1: 110-130%, Auto-recovery, adaptive to selected PDO Level 2: 24-28V, Latched off, cycle AC to reset |
|---|
| Over-Current Protection: | 110-130%, Auto-recovery, adaptive to selected PDO |
|---|
| Short-Circuit Protection: | Auto-recovery |
|---|
| Over-Temperature Protection: | Auto-recovery |
|---|
Environmental| MTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
|---|
| Operating Temperature: | -10°C to 40°C (full load) |
|---|
| Storage Temperature: | -40°C to 80°C |
|---|
| Humidity: | 0% to 95% relative humidity, non-condensing |
|---|
| Altitude | 5000m |
|---|
| Cooling: | Convection |
|---|
| RoHS: | Complies with EU 2011/65/EU and China SJ/T 11363-2006 |
|---|
Safety| Dielectric Withstand Voltage: | 4000VAC or 5656VDC from input to output 10mA, 1 minute |
|---|
| Touch Current: | NC: 80µA max. SFC: 400µA max. |
|---|
| Earth Leakage Current | 300µA max. NC/SFC (N/A for 2-conductor input models) |
|---|
| Means of Protection: | 2 x MOPP |
|---|
| Output Isolation Options: | -Q suffix: Class II 2-conductor (interchangeable blades) -T2 suffix: Class II 2-conductor -T3 suffix: Class II, with functional earth (FE) Class I, earth wire connected directly to output negative |
|---|
| Note 3: | Review output isolation options with our article: PSU Isolation and Identify |
|---|
EMC| Applicable Standards: | Medical: EN 60601-1-2 (4e) Emissions: EN55032, EN61000-6-3, EN61000-6-4 Immunity: EN55024, EN61000-6-1 (4e), EN61000-6-2 (4e) |
|---|
| Conducted Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
|---|
| Radiated Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
|---|
| Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
|---|
| Voltage Fluctuations/Flicker: | EN61000-3-3 |
|---|
| Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 10KV contact discharge, 18KV air discharge, Criterion A |
|---|
| Radiated RF Immunity: | EN61000-4-3, 10V/m @ 80-1000MHz, 3V/m @ 1-2.7GHz, 80% 1KHz AM, Criterion A |
|---|
| EFT/Burst Immunity: | EN61000-4-4, 4KV/100KHz., Criterion A |
|---|
| Line Surge Immunity: | EN61000-4-5, 2KV differential, 4KV common-mode, Criterion A |
|---|
| Conducted RF Immunity: | EN61000-4-6, 10VRMS, 80% 1KHz AM, Criterion A |
|---|
| Voltage Dip Immunity: | EN61000-4-11, Criterion B/C |
|---|
| Note 4: | When a Class II power supply is connected to an earth-referenced system, conducted/radiated EMI levels tend to increase since the distant earth connection creates a long return path for common-mode EMI currents. This model includes an output common-mode choke to help alleviate system-level EMI issues. This choke can be removed for cost-sensitive applications. |
|---|
Enclosure| Housing: | High impact plastic, 94V0 polycarbonate, non-vented |
|---|
| Markings: | Adhesive backed label or laser engraving |
|---|
Security| USB Power Delivery: | Two non-standard voltage profiles are included: 5.8V and 15.1V. System designers may use these non-standard profiles to reduce the likelihood of system operation with non-GlobTek power supplies. 12.0V is also not standard, but is often included in other power supplies.
The power supply will respond to a USB PD “Discover Identity” VDM with 0x4754 in the “ProductID” field. USB PD host systems may check this value before initiating/allowing power negotiation. |
|---|
| Note 5: | These measures do not guarantee a secure implementation, and are only suggested as a method of risk mitigation. |
|---|
| Note 6: | Please see our article Product Security and Risk Mitigation for USB Power Delivery (PD) Based Systems for additional information. |
|---|
Special OptionsNon-standard - Contact GlobTek - Custom housing and output cord colors
- Custom fixed output cord length, for applicable models (1m, 2m, 3m lengths)
- Custom markings and marking methods
- Custom USB PD PDOs: Output voltages selectable between 5V and 20V, in 100mV increments
|