GTM968000P Open Frame/Internal ICT / ITE / Medical Power Supply

Information
Model NumberGTM968000P
CE EC-Declaration for Medicalhttps://cs.globtek.info/ec_declaration?id=a0O3a00000OA4O6EAL
CE EC-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ec_declaration?id=a0O3a00000OA4O6EAL
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://cs.globtek.info/ukca_declaration?id=a0O3a00000OA4O6EAL
UKCA-Declaration for Industrial/Commercial/ITEhttps://cs.globtek.info/ukca_declaration?id=a0O3a00000OA4O6EAL
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O3a00000OA4O6EAL
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000OA4O6EAL
Prop 65 Statementhttps://www.globtek.com/r2/PH7CNf
REACH Declarationhttps://www.globtek.com/r2/eM2co8
Conflict Minerals Declarationhttps://www.globtek.com/r2/vZY8R5
Model Parameters
TypeOpen Frame/Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)6A
Max Output Power Rating (W)800
Output Voltage Range (V)12-54
Auxiliary/Fan Output Voltage (V)12
Auxiliary/Fan Output Power (W)14.4W Forced Air, 10W Convection
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionN/A
Size (mm)127.0 (L) x 76.2 (W) x 34.3 (H)
EnclosureUser-added image

 
Rating Table
Model Number (Final ordering #/Part No to be defined)Output NumberVoltageAmps (Convection)Amps (Forced Air)Watts (Convection)Watts (Forced Air)RFQ
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90 - 264Vac, (85 - 264Vac with derating)
Nameplate: 100 - 240Vac
Input Frequency:Specified: 47 - 63Hz
Nameplate: 50 - 60Hz
No Load Input Power:< 1.5W @ 115V/230V
Inrush Current:60A max @ 264Vac
Power Factor:>0.95 @ 115Vac, >0.95 @ 230Vac, full load 

Main Output

Output Power:520W  (linearly derated to 480W @ 85Vac) [natural convection, open U-frame version]
800W  (linearly derated to 720W @ 85Vac) [forced air cooling, enclosed version] 
Constant Current Operation:CC/CV with a brick-wall CC limit at ~115% nominal current rating. Power supply enters auto-recovery (hiccup) mode once Vout drops to ~75% of nominal value.
Turn-on Delay:< 2 seconds @ 85Vac (full load)
Voltage Set-Point Tolerance:± 2.0% (measured at connector, no load, Ta = -20 to 50°C)
Load Regulation:± 1.0% (measured at connector)
Line Regulation:± 0.5% (measured at connector)
Ripple:1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Transient Response:<5% deviation (with 25-75% load step), recovery to within 1% in 1ms
Startup Overshoot:<5% (full load)
Hold-up Time:20ms min. (full load)

Standby Output

Output Voltage:5V
Output Current:1A
Line/Load Regulation + Set-Point Tolerance:± 4%
Ripple:1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Always on?Yes

Fan Output

Output Voltage:12V
Output Current:0.6A
Line/Load Regulation + Set-Point Tolerance:± 4%
Always on?On or off depending on internal sensed temperature

Other Control & Signaling Features

Remote On/Off (EN)Yes
Remote Voltage Sense:Yes, voltage drop compensation up to 500mV of total drop, short and reverse polarity protected
Power Good (PG)Yes
Automatic On/Off Fan Control:Yes, dependent on internal temperature, with hysteresis
Main output voltage adjustment:Yes, ± 10% adjustment range via trimmer potentiometer (special option)

Protections

Fusing:Dual, high-breaking-capacity fuses compliant to IEC60601-1, ≥1,500A breaking capacity
Over-Voltage Protection:110 - 130%. Latched-off, cycle AC to reset
Over-Current Protection:115% typical, CC operation when Vout is between 75 - 100% of nominal value, auto-recovery hiccup-mode when Vout collapses to <75% of nominal value
Short Circuit Protection:Auto-recovery
Over-Temperature Protection:Latched-off, cycle AC to reset
AC Under-Voltage Protection:Brown-out trip @ 70Vac (nom.), Restore @ 75 - 80Vac

Environmental

Operating Temperature:-20°C to 50°C (full output power), -20°C to 70°C (linearly derated to 50% power rating @ 70°C)
Storage Temperature:-30°C to 85°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m max.
Vibration:Conforms to EN60068-2-6, ISO80601-2, EN1789

Safety

Certifications:IEC60601-1
IEC62368-1
IEC60335-1
Dielectric Withstand Voltage:4000VAC or 5656VDC, primary-to-secondary
3000VAC or 4242VDC, primary-to-earth
3000Vac or 4242VDC, secondary-to-earth (Class II FE models only, N/A for Class I)
Suitable Medical Applications:Type-B (Class I) or Type-BF (Class II with FE)
Output Touch Current:NC: <80µA, SFC: <400µA (open neutral, open earth)
Earth Leakage CurrentNC: <300µA, SFC: <1.0mA (open neutral)
Means of Protection:2 x MOPP (primary-to-secondary), 1xMOPP (primary-to-earth), 1xMOPP (secondary-to-earth, Class II FE models only)

EMC

Certifications:IEC60601-1-2
EN55032 (CISPR32)
EN55035 (CISPR35)
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load, Class I and Class II FE configurations)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load, Class I and Class II FE configurations)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge (applied to output terminals, and to horizontal/vertical coupling planes [HCP/VCP] with power supply sitting on HCP) 
Radiated RF Immunity:EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 30A/m
Voltage Dip Immunity:EN61000-4-11

Mechanical

Dimensions:U-Frame version: 6.00"  x 4.00" x 1.69" (152.3mm x 101.6mm x 43.0mm)
Enclosed version with top-side fan: 6.00" x 4.00" x 2.40" (152.3mm x 101.6mm x 61.0mm)
Fan Audible Noise Specification:28.5dB(A) (Enclosed version with fan only)

Input/Output Connectors

Input Connector (J1):Connector on PCB: TE Connectivity/AMP 641966-1
Recommended mate: TE Connectivity/AMP 350766-1
Pinout: 1: Neutral | 2: Not used | 3: Line
Main Output Connectors (J2, J3):Connector on PCB: CNNT ACTB207 (M5 ring terminal),
Recommended mounting torque: 2.0Nm
Recommended mate: Various, depends on required wire size
Pinout:
J2: V+ | J3: V- (GND)
Standby/Control Output Connector (J4):Connector on PCB: Molex 0705550005
Recommended mate: Molex 0014562062
Pinout: 1: SNS+ | 2: SNS- | 3: PGOOD | 4. EN | 5. GND | 6. +5VSB
Fan Output Connector: (J5):Connector on PCB: Molex 22-04-1021
Recommended mate: Molex 22-01-1022
Pinout:1: GND | 2: +FAN
Earth Connector (J6):Connector on PCB: Kang Yang PCH250 (0.250" x 0.031" Faston)
Recommended mate: TE Connectivity/AMP 2-520184-2

 

Derating CurveUser-added image
User-added image
Qty (ea.)/Carton
Individual Box/Gift Box Size (mm)
Individual Box/Gift Box Color
Master Carton Size (mm)TBD
Gross Weight (kg)
Label Width (mm)TBD
Label Height (mm)TBD
Input Configuration
DescriptionnullUser-added image
 
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Request Info