Preferred ratings shown below. Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined)
Voltage (V)
Current (A)
Power (W)
LPS
RFQ
GTM96900P9015-T3A*
15
6
90
N
GTM96900P9018-T3A*
18
5
90
null
GTM96900P9019-T3A*
19
4.73
89.87
N
GTM96900P9012-T3A*
12
7.5
90
null
GTM96900P9012.8-T3A*
12.8
7
89.6
null
GTM96900P8512-T3A*
12
7.1
85.2
N
GTM96900P9013-T3A*
13
6.92
89.96
null
GTM96900P9014-T3A*
14
6.428
89.99
null
GTM96900P9017-T3A*
17
5.294
90
null
GTM96900P9020-T3A*
20
4.5
90
null
GTM96900P9021-T3A*
21
4.285
89.99
null
GTM96900P9022-T3A*
22
4.09
89.98
null
GTM96900P9023-T3A*
23
3.913
90
null
GTM96900P9025-T3A*
25
3.6
90
null
GTM96900P9026-T3A*
26
3.461
89.99
null
GTM96900P9027-T3A*
27
3.333
89.99
null
GTM96900P9028-T3A*
28
3.214
89.99
null
GTM96900P9029-T3A*
29
3.103
89.99
null
GTM96900P9031-T3A*
31
2.903
89.99
null
GTM96900P9032-T3A*
32
2.812
89.98
null
GTM96900P9033-T3A*
33
2.727
89.99
null
GTM96900P9034-T3A*
34
2.647
90
null
GTM96900P9036-T3A*
36
2.5
90
N
GTM96900P9037-T3A*
37
2.432
89.98
null
GTM96900P9038-T3A*
38
2.368
89.98
null
GTM96900P9039-T3A*
39
2.307
89.97
null
GTM96900P9040-T3A*
40
2.25
90
null
GTM96900P9041-T3A*
41
2.195
90
null
GTM96900P9042-T3A*
42
2.142
89.96
null
GTM96900P9043-T3A*
43
2.093
90
null
GTM96900P9044-T3A*
44
2.045
89.98
null
GTM96900P9045-T3A*
45
2
90
null
GTM96900P9046-T3A*
46
1.956
89.98
null
GTM96900P9047-T3A*
47
1.914
89.96
null
GTM96900P9049-T3A*
49
1.836
89.96
null
GTM96900P9050-T3A*
50
1.8
90
null
GTM96900P9051-T3A*
51
1.764
89.96
null
GTM96900P9052-T3A*
52
1.73
89.96
null
GTM96900P9053-T3A*
53
1.698
89.99
null
GTM96900P8512-T3AZ*
12
7.1
85.2
Y
GTM96900P9015-T3AZ*
15
6
90
Y
GTM96900P9024-T3AZ*
24
3.75
90
Y
GTM96900P9030-T3AZ*
30
3
90
Y
GTM96900P9036-T3AZ*
36
2.5
90
Y
GTM96900P9048-T3AZ*
48
1.875
90
Y
GTM96900P9054-T3AZ*
54
1.66
89.64
Y
GTM96900P9012.5-T3AZ*
12.5
7.2
90
Y
GTM96900P9030-T3A*
30
3
90
N
GTM96900P9029.4-T3A*
29.4
3.061
89.99
null
GTM96900P9012.5-T3A*
12.5
7.2
90
null
GTM96900P9016-T3A*
16
5.625
90
null
GTM96900P9024-T3A*
24
3.75
90
N
GTM96900P9035-T3A*
35
2.57
89.95
null
GTM96900P9048-T3A*
48
1.875
90
N
GTM96900P9054-T3A*
54
1.66
89.64
N
GTM96900P90VV.V-T3A-XXXX
CUSTOM
CUSTOM
CUSTOM
CUSTOM
* (Final ordering #/Part No to be defined)
Specifications
Input
Input Voltage:
Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 90% rated load current for 85-264VAC 100% rated load current for 90-370VDC
Input Frequency:
Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:
0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:
< 150mW @ 115/230VAC
Inrush Current:
< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:
DoE Level VI and EU CoC Tier 2 compliant
Output
Turn-on Delay:
1 second typ.
Output Regulation:
± 4% (measured at output connector)
Line Regulation:
± 0.5% typ. (measured at output connector, full load)
Ripple:
1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:
5% max.
Transient Response:
5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:
20ms min.
Power Indicator:
Green LED
Switching Frequency:
Variable, 25KHz - 125KHz, depending on load
Output Type:
Z-suffix only: IEC62368-1 Limited Power Source (LPS), 8A and 100W max.
Protections
Input Protection:
300VAC MOV transient suppressor, input line fusing
Over-Current Protection (Non-LPS Version):
110 - 160% of rated output current, auto-restart
Over-Current Protection: (LPS "Z" Version)
Overload limited to less than 8A and less than 100W, auto-restart
Short-Circuit Protection:
Auto-restart
Over-Voltage Protection:
110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature Protection
On-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~150°C, restart at Tj = ~140°C
Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:
Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option
Safety
Dielectric Withstand Voltage:
4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:
Class I: 20µA max. Class II: 70µA max.
Earth Leakage Current
Class I: 300µA max. Class II: N/A
Means of Protection:
2 x MOPP
Output Isolation Options:
Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:
Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:
< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:
See listing at end of this datasheet for specific standards
Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:
Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:
EN61000-3-2, Class A
Voltage Fluctuations/Flicker:
EN61000-3-3
Electrostatic Discharge (ESD) Immunity:
EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:
EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:
EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:
EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:
EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:
EN61000-4-8, 3A/m
Voltage Dip Immunity:
EN61000-4-11
Enclosure
Housing:
High impact plastic, 94V0 polycarbonate, non-vented
Size:
149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:
C6, C8, C14, or C18 IEC inlet
Markings:
Label and/or pad printed and/or laser-etched into case
Special Options
IEC62368-1 Limited Power Source (LPS) version (add Z suffix)
Reduced leakage current to meet IEC60601-1 Type-CF limits
Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C), available in three load ranges: 27-45W, 40-60W, and 60-90W
Ruggedized construction with improved shock and vibration resistance
Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
Short term output surge capability for motors or other high peak current loads (non-LPS version only)
Custom cordsets, special cordage and connector types
Custom housing markings
Custom housing/cordage colors
Tightened output voltage tolerance
Reduced output ripple level
Reduced output power rating
Low temperature option, down to -40°C
Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
"Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
Improved ingress protection (IP) rating
Output Connectors
Several output connector options are available with various output current ratings. GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our 10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or package with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016
RCM certificate GMA-514113-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
CCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
Patent pending
Patent pending
Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
IRAM certificate DC-E-G71-005.1 to IEC 62368-1:2014
ETL (Brazil) to IEC 62368-1;2014 DOC cert
UKCA Certification
UL1310 Warning Label Up To 36 Volts with plugs
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2]
LPS
Limited Power Source if Z suffix on model number 62368
CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
Information Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] up to 5A Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
No Logo Applicable
CB for IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition)
Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance (R2012) [AAMI ES60601-1:2005 +C1;A2] [CSA C22.2#60601-1:2014 Ed.3] [AAMI HA60601-1-11:2015 Ed.2]
No Logo Applicable
CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
null
Indoor Use Only - Mark is on the label or Molded in the case
IP41
Ingress Protection: ?IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPS
Limited Power Source if Z suffix on model number
RoHS
Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
Japan: Voluntary Control Council for Interference (VCCI)
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb