Model Number (Final ordering #/Part No to be defined)
Voltage (V)
Current (A)
Power (W)
RFQ
GT-46400-3612-T2*
12
3
36
GT-46400-3615-2.0-T2*
13
2.76
35.88
GT-46400-3615-1.0-T2*
14
2.57
35.98
GT-46400-3315-0.5-T2*
14.5
2.27
32.92
GT-46400-4015-T2*
15
2.66
39.9
GT-46400-4019-3.0-T2*
16
2.5
40
GT-46400-4019-2.0-T2*
17
2.35
39.95
GT-46400-4019-1.0-T2*
18
2.22
39.96
GT-46400-4019-T2*
19
2.1
39.9
GT-46400-4024-4.0-T2*
20
2
40
GT-46400-4024-3.0-T2*
21
1.9
39.9
GT-46400-4024-2.0-T2*
22
1.81
39.82
GT-46400-4024-1.0-T2*
23
1.73
39.79
GT-46400-4024-T2*
24
1.66
39.84
GT-46400-4048-T2*
48
0.83
39.84
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Inrush Current: NO Damage 04. Efficiency: Compliant with Efficiency Level VI and CoC Tier 2 standards 05. No Load Standby Power: <0.075W @ 230Vac 06.Load regulation: ±5% 07. Output Voltage: Tolerance ± 5% 08. Ripple Voltage: 120mV (p-p): Input :(100V-240VAC ), Output:full load Ripple&Noise test: Use 20MHz band width frequency oscilloscope.Add 0.1uF/47uF Capacitor output connector terminal
B) PROTECTION 01. Over voltage protection: ≦16V 02. Short circuit protection: Output shut down and auto- recover 03. Over Load Protection: ≦ 5A output load
C) SAFETY 01. HI-POT : Input to output : 3000VAC 10mA 1 minute (for Class II), 1500VAC 10mA 1 minute(for Class I) 02. Insulation resistance: Input to output: 500vdc to test the input to output resistance not be less 100M ohm 03. Touch Current: <0.25mA @ 240Vac input voltage
D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 40°C ambient temperature 03. Humidity Operating : 20% to 80%. 0% to 90% relative humidity 04. Storage Temperature: -10°C to 70°C Humidity Storage: 10% to 90% 05. RoHS 2: Complies with EU 2011/65/EU andChina SJ/T 11364-2014
E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Size: 111.0 x 52.0 x 32.3 +/-1.0 mm 03. Markings: Label and/or Pad Printed and/or Molded in the case
Derating Curve
Qty (ea.)/Carton
54
Individual Box/Gift Box Size (mm)
Egg Crate
Individual Box/Gift Box Color
Egg Crate
Master Carton Size (mm)
546 x 413 x 217
Gross Weight (kg)
9.6
Label Width (mm)
37.5
Label Height (mm)
77.5
Input Configuration
Description
IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
Mates with IEC 60320/C7 Plug
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
No Logo Applicable
EU 230V CoC Tier 2, 278/2009, Mar 2014
Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
UKCA Certification
UL 62368-1 and CAN/CSA C22.2 No. 62368-1-14
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
NOM (Mexico) to NOM-001-SCFI-1993 GT-46400-3612-T2
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
JAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: https://www.globtek.com/r2/Szj4Vb
RoHS
Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
Indoor Use Only - Mark is on the label or Molded in the case
Ingress Protection: ?IP40 to IEC60529:2001 Protection against granular foreign bodies (with I/P cord)
Japan: Voluntary Control Council for Interference (VCCI)
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
LPS
Limited Power Source 60950
UL60950-1, cULus to UL 60950-1 E170507
No Logo
IEC 60950-1: 2005 (Second Edition) + Am 1: 2009 + Am 2: 2013
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition)
JAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb
Compliance of this power supply with FCC Part 15, Class B has been demonstrated with a standard output load. The FCC law stipulates that system-level testing is required to demonstrate compliance with the FCC emission limits with the actual system load.