GTM86100-10VV-W2U-USBC | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GTM86100-10VV-W2U-USBC, ICT / ITE / Medical Power Supply, Wall Plug-in, AC/DC Switching Adapter with USB Power Supply AC Adaptor, , Input Rating: 100-240V~, 50/60Hz, UK BS 1363, 2 Blade w/Dummy Ground Class II, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5-5.2V in 0.1V increments, Approvals: | |||||||||||||||||||||||
Information | |||||||||||||||||||||||
Model Number | GTM86100-10VV-W2U-USBC | ||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM86100/ | ||||||||||||||||||||||
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0OVv000002GwbZMAS | ||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0OVv000002GwbZMAS | ||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0OVv000002GwbZMAS | ||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0OVv000002GwbZMAS | ||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0OVv000002GwbZMAS | ||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0OVv000002GwbZMAS | ||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||
Technology | AC/DC Switching Adapter with USB Power Supply AC Adaptor | ||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply | ||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50/60Hz | ||||||||||||||||||||||
Max Input Current (A) | 0.3A | ||||||||||||||||||||||
Max Output Power Rating (W) | 10 | ||||||||||||||||||||||
Output Voltage Range (V) | 5-5.2 | ||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||
Ingress Protection | |||||||||||||||||||||||
Size (mm) | 60.0*41.2*48.9 +/-1.0 | ||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||
3D File Download | https://www.globtek.com/file/dl/gtm86100-10vv-w2k-usb_asm.stp | ||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||
Specifications | |||||||||||||||||||||||
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz 03. Output Regulation: +/- 5% measured at the end of a 1 meter USB cordset employing #20 Gauge conductors 04. Line Voltage Regulation: +/- 1% typical measured at the end of a 1 meter USB cordset employing #20 Gauge conductors 05. Output Ripple (Vp-p): 1% or 100 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector 06. Hold-up Time: 5 mS minimum 07. Inrush Current: 30A maximum @ 230Vac input 08. Energy Efficiency: Complies to Efficiency Level VI and ErP European Commission's Ecodesign Directive (2005/32/EC) / CoC Tier 2 Compliant B) PROTECTION 01. Over-current protection: 110%-140% maximum with auto-recovery function 02. Output Over-Voltage: 110% to 130% of nominal output voltage 03. Short-circuit protection: The adapter shall not be damaged by short the DC output to Ground. C) SAFETY 01. Dielectric Withstand Voltage: Primary To Secondary: 4000VAC or 5656VDC for 3 seconds 02. Leakage Current: 50uA maximum, at nominal 240Vac input voltage 03. ESD Immunity per EN61000-4-2, ±8 kV contact, ±15 kV air, Perf Criteria A Standard. D) EMC 01. Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B 02. Line Frequency Harmonics EN61000-3-2, Class A 03. Voltage Fluctuations/Flicker EN61000-3-3 04. Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 8kV Contact Discharge, 15kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m 80-2700MHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 2kV/100kHz. Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, NA Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 01. MTBF: 300,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 50°C ambient temperature 03. Operating Humidity: 20 ~ 85 % RH. non-condensing 05. Storage Temperature: -20°C to 60°C 06. Storage Humidity:5 ~ 95 % RH. non-condensing 07. Cooling: Natural convection cooling 08. RoHS 2: Complies with EU 2011/65/EU China SJ/T 11364-2014 F) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case F) OPTIONS: 01. Green Power On Indicator LED 02. NEMA 1-15P or European Schuko 7-16 AC Plug Configuration 03. Increased DC Output Voltage (up to 5.4V) to allow for long output cables 04. Special International Safety Approvals 05. Housing Color, special markings | |||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||
Qty (ea.)/Carton | 300 | ||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 43(L)*30(W)*75 | ||||||||||||||||||||||
Individual Box/Gift Box Color | 43(L)*30(W)*75 | ||||||||||||||||||||||
Master Carton Size (mm) | 485 x 335 x 305 | ||||||||||||||||||||||
Gross Weight (kg) | 12 | ||||||||||||||||||||||
Label Width (mm) | 37.0 | ||||||||||||||||||||||
Label Height (mm) | 19.0 | ||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||
Description | UK BS 1363, 2 Blade w/Dummy Ground Class II The line and neutral pins have a rectangular cross section 6.35 mm by 4.0 mm, 17.7 mm long and with centres 22.2 mm apart. The protective-earth pin is a rectangular cross section 8.0 mm by 4.0 mm, 22.3 mm long and with a centre line 22.2 mm from the line/neutral pin centre line. The dimensions were originally specified in decimal inches with asymmetric tolerances and redefined as minimum and maximum metric dimensions in BS 1363:1984. | ||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. |