GT-83083-0505-USB-W2U Wall Plug-in ICT/ITE Power Supply
GT-83083-0505-USB-W2U | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GT-83083-0505-USB-W2U, ICT/ITE Power Supply, Wall Plug-in, AC/DC Switching Adapter with USB Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, UK BS 1363 configuration: UK 2 Blades Class I, Output Rating: 5 Watts, Power rating with convection cooling (W) , 5V in 0.1V increments, Approvals: UKCA; LPS 62368; UKCA; China RoHS; Double Insulation; Level VI; RoHS; CE; WEEE; CB 60950; LPS 60950; SIQ; | |||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||
Model Number | GT-83083-0505-USB-W2U | ||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-83083-USB-W2Z/ | ||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0Oa000000MEmxJEAT | ||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0Oa000000MEmxJEAT | ||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000MEmxJEAT | ||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MEmxJEAT | ||||||||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||||||||||
Technology | AC/DC Switching Adapter with USB Power Supply AC Adaptor | ||||||||||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60Hz | ||||||||||||||||||||||||||||||
Max Input Current (A) | 0.2A | ||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 5 | ||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5 | ||||||||||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||||||||||
Ingress Protection | |||||||||||||||||||||||||||||||
Size (mm) | 49.2*47.0*27.5 +/-0.3 | ||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||
3D File Download | https://www.globtek.com/file/dl/gt-83083-0505-usb-w2u_asm.stp | ||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 03. Output Regulation: +/- 5% measured at the output connector measured at the end of a 0.6 meter USB cordset employing #22 Gauge conductors 04. Line Voltage Regulation: +/- 1% typical measured at the output connector measured at the end of a 0.6 meter USB cordset employing #22 Gauge conductors 05. Output Ripple (Vp-p): +/-1% or 100 mV whichever is greater measured at the end of a 0.6 meter USB cordset employing #22 Gauge conductors. Measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector. 06. Inrush Current: at full load, 25°C, cold start 07. Switching Frequency: 100 KHz typical, varies with line and load 08. Efficiency: 73.77% minimum at nominal input voltage average, Efficiency meet CEC Ⅴ, ERP:2009/125/EC B) PROTECTION 01. Over-current protection: 1.5A maximum with auto-recovery function 02. Over-voltage protection: 10VDC maximum with zener clamp 03. Short-circuit protection:The adapter shall not be damaged by short the DC output to Ground. C) SAFETY 01. Dielectric Withstand Voltage: Primary To Secondary: 3000VAC 10mA 1minute or 4242VDC 10mA 1minute 02. Leakage Current: 20uA maximum, at nominal AC input voltage and frequency 03. ESD Immunity per EN61000-4-2, ±8 kV contact, ±15 kV air, Perf Criteria A Standard. D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 50°C ambient temperature 03. Operating Humidity: 20 ~ 85 % RH. non-condensing 05. Storage Temperature: -20°C to 60°C 06. Storage Humidity:5 ~ 95 % RH. non-condensing 07. Cooling: Cooling shall be with natural convection cooling 08. RoHS 2: Complies with EU 2011/65/EU China SJ/T 11364-2014 E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||
Qty (ea.)/Carton | TBD | ||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | Egg Crate | ||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||
Master Carton Size (mm) | TBD | ||||||||||||||||||||||||||||||
Gross Weight (kg) | TBD | ||||||||||||||||||||||||||||||
Label Width (mm) | 30.0 | ||||||||||||||||||||||||||||||
Label Height (mm) | 24.0 | ||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||
Description | UK BS 1363 configuration: UK 2 Blades Class I | ||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||
|