GT-41134-06VV-x.x-Q (Constant Current) Wall Plug-in ICT/ITE Power Supply
GT-41134-06VV-x.x-Q (Constant Current) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | GT-41134-06VV-x.x-Q (Constant Current), ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-48V in 0.1V increments, Approvals: RCM; UKCA; CB 62368; S-Mark 62368; CCC; CE; China RoHS; China RoHS; Double Insulation; EC; Level V >1m; WEEE; LPS 60950; CB 62368; NrCAN; RoHS; Ukraine; VCCI; FCC; UL/cUL; CB 60950; EAC; PSE; GT-41134-06VV-x.x-Q (Constant Current), ICT/ITE Power Supply, Wall Plug-in, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Blade Options for Q Series Wall Plug-in Power Supplies, Output Rating: 6 Watts, Power rating with convection cooling (W) , 3.3-48V in 0.1V increments, Approvals: RCM; UKCA; CB 62368; S-Mark 62368; CCC; CE; China RoHS; China RoHS; Double Insulation; EC; Level V >1m; WEEE; LPS 60950; CB 62368; NrCAN; RoHS; Ukraine; VCCI; FCC; UL/cUL; CB 60950; EAC; PSE; | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Model Number | GT-41134-06VV-x.x-Q (Constant Current) | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GT-41134%20Interchangeable/ | ||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0Oa000000HSgisEAD | ||||||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0Oa000000HSgisEAD | ||||||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000HSgisEAD | ||||||||||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000HSgisEAD | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://en.globtek.com/prop-65-statement.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/pdf/iso_certificates/REACH.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/pdf/conflict-minerals.pdf | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Type | Wall Plug-in | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Category | ICT/ITE Power Supply | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 3.3-48 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | V | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 43.5 x 74.0 x 35.3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: 100-240 Vac 02. Input Current: 0.6 A RMS max 03. Input Frequency: 47 - 63 Hz 04. Output Voltage Regulation: +/- 5% measured at the output connector 05. Output Current Regulation in CC Mode: +/- 10% measured at the output connector 06. Line Voltage Regulation: +/- 1% typical measured at full load 07. Output Ripple (Vp-p): +/-1% or 150 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line 08. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load 09. Turn-ON Delay: 3000 mS, maximum @ full load, nominal line 10. Hold-Up Time: 8 mS typical @ nominal input voltage and full load 11. Inrush Current: 30A maximum cold start @ 240Vac input 12. Switching Frequency: 65 KHz typical B) PROTECTION 01. Over-Voltage: Electronically Protected Zener clamp across the output 02. Short Circuit: Electronically Protected unit will auto recover upon removal of fault 03. Input Protection: Input line fusing 04. Over Load Protection: Protected, Unit will automatically recover upon removal of fault C) SAFETY 01. Dielectric Withstand Voltage: 4242Vdc from primary to secondary 02. Earth Leakage Current: <10 uA at 240Vac input voltage D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature: 0°C to 40°C ambient temperature 03. Humidity: 0% to 90% relative humidity 04. Storage Temperature: -10°C to 80°C 05. Cooling: Convection E) ENCLOSURE 01. Housing: High impact plastic, 94V0 polycarbonate, non-vented 02. Size: 43.5 x 74.0 x 35.3 mm +/-1.0 mm 03. Markings: Label and/or Pad Printed and/or Molded in the case | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 60 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 100x90x58mm | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 478 x 421 x 200 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 16.5 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 29.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 20.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Blade Options for Q Series Wall Plug-in Power SuppliesData Sheet: http://en.globtek.com/interchangeable-blades.php Insertion Instructions: http://www.globtek.com/pdf/Instructions-Interchangeable-Blades.pdf Video: Q-Blade Style Instruction Video INPUT CONNECTOR: Q-Socket (below are available blades configurations which are "not included" (unless stated above); can be purchased separately, package with power supply or as a separate "Q-KIT" if specified 01. United States / Canada / Japan NEMA 1-15P/ IEC PLUG Type A [WORKS IN PLUG B] configuration: NA 2 blades, Class II; US/CA/JP P/N: Q-NA(R) Kits 01. Q-KIT: 1,2,3,4 above | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
For a comprehensive list of options, click here Contact GlobTek for your specific requirements or custom solutions. | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||||||||||||||||||||||
|