Regulated Switchmode AC-DC Power Supply AC Adaptor
Category
ICT/ITE Power Supply
Input Voltage Range (V)
100-240V~, 50-60 Hz
Max Input Current (A)
0.6A
Max Output Power Rating (W)
18
Output Voltage Range (V)
5-24
Efficiency
IV
Ingress Protection
Size (mm)
80.6*50.0*31.0
Enclosure
Rating Table
Model Number (Final ordering #/Part No to be defined)
Voltage (V)
Current (A)
Power (W)
RFQ
GT-41062-1805-T3*
5
3.6
18
GT-41062-1806-T3*
6
3
18
GT-41062-1807-T3*
7
2.57
17.99
GT-41062-1809-T3*
9
2
18
GT-41062-0909-T3*
9
1
9
GT-41062-1812-T3*
12
1.5
18
GT-41062-1815-T3*
15
1.2
18
GT-41062-1818-T3*
18
1
18
GT-41062-1820-T3*
20
0.9
18
GT-41062-1824-T3*
24
0.75
18
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS: 1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz 3. Output Power (Rated): 18Watts max 4. Output Regulation: +/- 5% measured at the output connector 5. Line Voltage Regulation: +/- 1% typical measures at full load 6. Output Ripple (Vp-p): 1% or 150 mV whichever is greater measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of output connector at nominal line 7. Turn-On/Turn-Off Overshoot: 5% maximum, 1mS typical recovery time for 25% step load 8. Turn-On Delay: 1 second typical 09. Hold-Up Time: 8mS typical @ nominal input voltage & full load 10. Inrush Current: 30A typical @ 115Vac input ; 60A typical @ 230Vac input 11. Switching Frequency: 65 KHz typical
B) PROTECTION 1. Over-Voltage: Protected via zener diode across the output 2. Short Circuit: Electronically Protected, unit will recover upon removal of fault 3. Input Protection: Input line fusing
C) SAFETY 1. Dielectric Withstand Voltage: 4242Vdc from primary to secondary 2. Touch Current: <0.25mA @ 240Vac input voltage 3. Earth Leakage Current: <3.5mA @ 240Vac input voltage 4. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006 4. Earth continuity test:<0.1 Ohm or < 0.2 Ohm when with a non-detachable Power Supply cord, Class I Only
D) OTHER: 1. MTBF: 200,000 hours @ 25°C ambient temperature 2. Operating Temperature: 0°C to 40°C ambient temperature 3. Humidity: 0% to 90% relative humidity 4. Storage Temperature: -10°C to 80°C
E) ENCLOSURE 1. Upper Housing: High impact plastic, 94V0 polycarbonate, non-vented 2. Lower Housing: High impact plastic, 94V0 polycarbonate, non-vented 3. Size: 80.5* 50.0*31.0 mm +/-1.0
Derating Curve
Qty (ea.)/Carton
80
Individual Box/Gift Box Size (mm)
57*110*70
Individual Box/Gift Box Color
57*110*70
Master Carton Size (mm)
450 x 295 x 285
Gross Weight (kg)
15.6
Label Width (mm)
39.6
Label Height (mm)
59.6
Input Configuration
Description
IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground Mates with IEC 60320/C13 Plug
Optional Locking IEC60320 Receptable and cord option available on some models by request.:
Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm (pending)
UKCA Certification
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition) + A11:2017
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
No Logo
CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011
CCC to GB 17625.1-2022 (Class A);GB 4943.1-2022;GB/T Tropical <2000 for GT-41062
CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
SIQ Mark License Certificate EN 60950-1:2006 + Am 1:2010+ Am 11:2009 + Am 12:2011
UL60950-1, cULus to UL 60950-1, 1st Edition, 2007-10-31 and CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07
Japan: Voluntary Control Council for Interference (VCCI)
Indoor Use Only - Mark is on the label or Molded in the case
RoHS
Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf
LPS
Limited Power Source 60950
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
JAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: https://www.globtek.com/r2/Szj4Vb
Korea KET KC Mark GT-41062-1809-T3 HU10499-9002A (9V Only)
Korea KET KC Mark GT-41062-1815-T3 HU10499-9002A (15V Only)
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)... NOTE: 24V & 1830 mm 18 - 20awg o/p cord only
JAPAN TUV R-PSE, Cert. No. JD 50680360., to J62368-1(2023) , J55032(H29), J3000(H25) ,[15V or less]. Please reference the following website for PSE regulations: https://www.globtek.com/r2/Szj4Vb
JAPAN TUV R-PSE, Cert. No. JD 50680360.pdf, to J62368-1(2023) , J55032(H29), J3000(H25) ,[15V?30V]. Please reference the following website for PSE regulations: https://www.globtek.com/r2/Szj4Vb
IRAM certificate DC-E-G71-001.1 to IEC 60950 + A1:2009