InputInput Voltage: | Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 90% rated load current for 85-264VAC |
---|
Input Frequency: | Specified: 47-63Hz, Nameplate: 50-60Hz |
---|
Power Factor: | 0.90 (min.) @ 230VAC, 0.97 (min.) @ 115VAC |
---|
No Load Input Power: | <150mW @ 230VAC (EU CoC Tier 2 compliant) |
---|
Inrush Current: | 30A/60A max. (cold start @ 115V/230VAC) |
---|
Efficiency: | DoE Level VI and EU CoC Tier 2 compliant |
---|
OutputTurn-on Delay: | 1 second typ. @ 115VAC and full load |
---|
Output Regulation: | ± 4% (measured at output connector) |
---|
Line Regulation: | ± 0.5% typ. (measured at output connector, full load) |
---|
Ripple: | 1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector) |
---|
Turn-On Overshoot: | 5% max. |
---|
Transient Response: | 5% max. deviation, 1ms recovery time (with 25% to 50% load step) |
---|
Hold-up Time: | 20ms min. |
---|
Switching Frequency: | 25 - 125KHz, depending on model and load condition |
---|
Power Indicator: | Green LED |
---|
ProtectionsInput Protection: | MOV transient suppressor, dual input line fusing |
---|
Over-Current Protection: | 105 - 140% of rated output current, auto-restart |
---|
Short-Circuit Protection: | Auto-restart |
---|
Over-Voltage Protection: | 110 - 135% (60V max. for output voltage ≥ 45V), latched off, cycle AC to reset |
---|
EnvironmentalMTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
---|
Operating Temperature: | -10°C to 40°C (full load) |
---|
Storage Temperature: | -30°C to 80°C |
---|
Humidity: | 0% to 95% relative humidity, non-condensing |
---|
Altitude: | 5000m |
---|
Cooling: | Convection |
---|
RoHS: | Complies with EU 2011/65/EU and China SJ/T 11363-2006 |
---|
Note 1: | Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option |
---|
SafetyDielectric Withstand Voltage: | 4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only) |
---|
Touch Current: | Standard models (No suffix): Class I: 20µA max. Class II: 70µA max. Class II with Functional Earth (F2): 20µA max.
Low-leakage models (-CF suffix): Class II with Functional Earth (F2): 10µA max. |
---|
Note 2: | Standard models are designed for use in Type-B/BF medical applications. Low-leakage models are designed for use in Type-CF medical applications. (See IEC60601-1, Clause 16.6.1) |
---|
Earth Leakage Current | Class I: 300µA max. Class II: N/A |
---|
Means of Protection: | 2 x MOPP |
---|
Output Isolation Options: | Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity. |
---|
Earth Continuity Test: | < 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only) |
---|
Compliant Standards: | See listing at end of this datasheet for specific standards |
---|
EMCApplicable Standards: | Medical: EN60601-1-2, 4th edition Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22 Immunity: EN55024, EN61000-6-1, EN61000-6-2 |
---|
Conducted Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
---|
Radiated Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
---|
Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
---|
Voltage Fluctuations/Flicker: | EN61000-3-3 |
---|
Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 10KV contact discharge, 18KV air discharge |
---|
Radiated RF Immunity: | EN61000-4-3, 10V/m 80-2700MHz, 80% 1KHz AM |
---|
EFT/Burst Immunity: | EN61000-4-4, 4KV/100kHz. |
---|
Line Surge Immunity: | EN61000-4-5, 2KV differential, 4KV common-mode |
---|
Conducted RF Immunity: | EN61000-4-6, 3VRMS, 80% 1KHz AM |
---|
Power Frequency Magnetic Field Immunity: | EN61000-4-8, 3A/m |
---|
Voltage Dip Immunity: | EN61000-4-11 |
---|
EnclosureMaterial/Construction: | High impact plastic, 94V0 polycarbonate, non-vented |
---|
Size: | 176.5 * 74.0 * 40.0mm (±1.0mm) |
---|
AC Input Mechanical Options: | Desktop: C6, C7, C14, or C18 inlet |
---|
Markings: | Label and/or pad printed and/or laser-etched into case |
---|
Special Options- Custom cordsets, cord types, and connector types
- Custom markings
- Custom housing and cordset colors
- Constant current/constant voltage (CC/CV) output behavior, with compliance voltage between (75% * Vout) and (100% * Vout)
- Short term output surge power capability, for motor applications and short term intermittent high power applications. (Up to 300W for 1 second.)
- IEC61000-3-2 Class C line harmonics for LED lighting applications
- "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
- Reduced touch/leakage current for IEC60601-1 Type-CF applications. (Available in models with -CF suffix.)
- High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
- Tightened output voltage tolerance
- Reduced output ripple level
- Reduced output power rating
- Improved ingress protection (IP) rating
Output Connectors |
Description | IEC 60320/C14 AC Inlet Connector, Class I, Earth Ground Mates with IEC 60320/C13 Plug
Optional Locking IEC60320 Receptable and cord option available on some models by request.:

Standard International IEC 320/C13 Cordsets
Below are standard cordsets which are "not included" (unless stated above); these can be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.Stock Power Supply Cords |
---|