Information |
|---|
| Model Number | GTM86100-10VV-W2-USB2C |
|---|
| Agency Documents | http://www.globtek.info/certs/GTM86100-USBC |
|---|
| CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0OVv000001dv7VMAQ |
|---|
| CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0OVv000001dv7VMAQ |
|---|
| CE EC-Declaration for Household | Contact GlobTek for more information |
|---|
| UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0OVv000001dv7VMAQ |
|---|
| UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0OVv000001dv7VMAQ |
|---|
| UKCA-Declaration for Household | Contact GlobTek for more information |
|---|
| Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0OVv000001dv7VMAQ |
|---|
| RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0OVv000001dv7VMAQ |
|---|
| Prop 65 Statement | https://www.globtek.com/r2/PH7CNf |
|---|
| REACH Declaration | https://www.globtek.com/r2/eM2co8 |
|---|
| Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 |
|---|
Model Parameters |
|---|
| Type | Wall Plug-in |
|---|
| Technology | AC/DC Switching Adapter with USB Power Supply AC Adaptor |
|---|
| Category | ICT / ITE / Medical Power Supply |
|---|
| Input Voltage Range (V) | 100-240V ̴ , 50/60Hz |
|---|
| Max Input Current (A) | 0.3A |
|---|
| Max Output Power Rating (W) | 10 |
|---|
| Output Voltage Range (V) | 5-5.2 |
|---|
| Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 |
|---|
| Ingress Protection | |
|---|
| Size (mm) | 56.5*23.9*38.9 +/-1.0 |
|---|
| Enclosure |

|
|---|
| 3D File Download | https://www.globtek.com/file/dl/gtm86100-10vv-w2_asm.sgtm86100-10vv-w2-usb_asm.stp |
|---|
Rating Table |
|---|
| Model Number (Final ordering #/Part No to be defined) | Voltage (V) | Current (A) | Power (W) | RFQ |
|---|
* (Final ordering #/Part No to be defined) |
Specifications |
|---|
Input| Input Voltage: | Specified: 85-264VAC, Nameplate: 100-240VAC |
|---|
| Input Frequency: | Specified: 47-63Hz, Nameplate: 50-60Hz |
|---|
| No Load Input Power: | <75mW @ 230VAC (EU CoC Tier 2 compliant) |
|---|
| Inrush Current: | 30A @ 115VAC, 60A @ 230VAC typ. (at peak of AC line, cold start) |
|---|
| Efficiency: | 78.7% min. (CEC&DOE Level VI compliant), 79.0% min. (EU CoC Tier 2 compliant) |
|---|
Output| Turn-on Delay: | 3 seconds max. |
|---|
| Rise-Time: | 100ms max. |
|---|
| Output Regulation | ± 5% (measured at the end of a 1.2m long 20AWG USB cordset) |
|---|
| Ripple: | 100mV (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW) |
|---|
| Transient Response: | 10% max. deviation (with 25-75% load step), 1ms max. recovery time |
|---|
| Hold-up Time: | 5ms min. (100VAC and full load) |
|---|
Protections| Input Protection: | MOV transient suppressor, input line fusing |
|---|
| Over-Current Protection: | 110% to 150%, auto-restart |
|---|
| Over-Voltage Protection: | 10VDC max. (Zener clamp) |
|---|
| Short-Circuit Protection: | Auto-restart |
|---|
| Over-Temperature Protection: | Auto-restart, on-chip temperature sensor |
|---|
Environmental| MTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
|---|
| Operating Temperature: | 0°C to 40°C (full load) |
|---|
| Operating Humidity: | 20% to 85% relative humidity, non-condensing |
|---|
| Storage Conditions: | -20°C to 60°C / 5% to 95% relative humidity, non-condensing |
|---|
| Cooling: | Natural convection |
|---|
Safety| Certifications: | IEC60601-1 IEC60601-1-11 IEC62368-1 |
|---|
| Dielectric Withstand Voltage: | 4000VAC or 5656VDC (primary-to-secondary) 5mA, 1 minute |
|---|
| Output Touch Current: | NC: 100µA max. SFC: 500µA max. |
|---|
| Earth Leakage Current | N/A, Class II input (No protective earth pin, therefore earth leakage is not measured) |
|---|
| Means of Protection: | 2 x MOPP (primary-to-secondary) |
|---|
EMC| Certifications: | IEC60601-1-2 EN55032 (CISPR32) EN55035 (CISPR35) |
|---|
| Conducted Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
|---|
| Radiated Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
|---|
| Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
|---|
| Voltage Fluctuations/Flicker: | EN61000-3-3 |
|---|
| Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 8KV contact discharge, 15KV air discharge, Criterion A |
|---|
| Radiated RF Immunity: | EN61000-4-3, 10V/m (80MHz-2.7GHz) |
|---|
| RF Wireless Communications Immunity: | EN61000-4-3, IEC60601-1-2 Subclause 8.10/Table 9, Criterion A |
|---|
| EFT/Burst Immunity: | EN61000-4-4, 2KV/100kHz., Criterion A |
|---|
| Line Surge Immunity: | EN61000-4-5, 2KV differential, Criterion A |
|---|
| Conducted RF Immunity: | EN61000-4-6, 3VRMS, 80% 1KHz AM, Criterion A |
|---|
| Power Frequency Magnetic Field Immunity: | EN61000-4-8, N/A |
|---|
| Voltage Dip Immunity: | EN61000-4-11, Criterion A/B |
|---|
Enclosure| Housing: | High impact plastic, PC 94V0, non-vented |
|---|
| Markings: | Laser marked or adhesive-backed label |
|---|
|
| Derating Curve |  |
|---|
| Qty (ea.)/Carton | 300 |
|---|
| Individual Box/Gift Box Size (mm) | 43(L)*30(W)*75 |
|---|
| Individual Box/Gift Box Color | 43(L)*30(W)*75 |
|---|
| Master Carton Size (mm) | 485 x 335 x 240 |
|---|
| Gross Weight (kg) | 12 |
|---|
| Label Width (mm) | 37.0 |
|---|
| Label Height (mm) | 19.0 |
|---|
Input Configuration |
|---|
| Description | NEMA 1-15P, North America Blades, Class II 2 ConductorsAll NEMA 1 devices are two-wire non-grounding devices (hot-neutral) rated for 125 V maximum. NEMA 1-15P plugs have two parallel flat blades, 0.25 inches (6.35 mm) wide, 0.06 inches (1.524 mm) thick, 0.625-0.718 inches (15.875–18.256 mm) long, and spaced 0.5 inches (12.7 mm) apart. |
|---|
Output Configuration |
|---|
Common output connector options: Click to add to your request.
| 
| 
| 
| 
| 
| | L Type (Coaxial 5.5x2.5mm plug) | C Type (Coaxial 5.5x2.1mm plug) | K Type (Coaxial 3.5x1.3mm plug) | LL Type (5.5x2.5mm Locking 760k type) | CL Type (5.5x2.1mm Locking S761k type) | Magnetic Connector | 
| 
| 
| 
| 
| | YL3 Type (KPPX-3P) | YL4 Type (KPPX-4P) | EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) | MSB Type (Micro USB) | Inquire for custom design |
![]()
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. |
| Approvals |
|---|
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. |
| Logo | Description |
|---|
| AAMI ES60601-1 Issued: 2012/08/20 Medical Electrical Equipment - Part 1: CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1: IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.- Part 1-11: | No Logo Applicable | IEC 60335-1:2010+A1+A2 | | No Logo Applicable | CB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements | No Logo Applicable | CB for IEC 62368-1:2014 (Second Edition) | | Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL 62368-1:2014 Ed.2] Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA C22.2#62368-1:2014 Ed.2] |
|