| GTM86100-10VV-W2U-USB2C |
|---|
 | GTM86100-10VV-W2U-USB2C, ICT / ITE / Medical Power Supply, Wall Plug-in, AC/DC Switching Adapter with USB Power Supply AC Adaptor, , Input Rating: 100-240V~, 50/60Hz, UK BS 1363, 2 Blade w/Dummy Ground Class II, Output Rating: 10 Watts, Power rating with convection cooling (W) , 5-5.2V in 0.1V increments, Approvals: |
|---|
Information |
|---|
| Model Number | GTM86100-10VV-W2U-USB2C |
|---|
| Agency Documents | http://www.globtek.info/certs/GTM86100-USBC |
|---|
| CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0OVv000002GwenMAC |
|---|
| CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0OVv000002GwenMAC |
|---|
| CE EC-Declaration for Household | Contact GlobTek for more information |
|---|
| UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0OVv000002GwenMAC |
|---|
| UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0OVv000002GwenMAC |
|---|
| UKCA-Declaration for Household | Contact GlobTek for more information |
|---|
| Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0OVv000002GwenMAC |
|---|
| RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0OVv000002GwenMAC |
|---|
| Prop 65 Statement | https://www.globtek.com/r2/PH7CNf |
|---|
| REACH Declaration | https://www.globtek.com/r2/eM2co8 |
|---|
| Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 |
|---|
Model Parameters |
|---|
| Type | Wall Plug-in |
|---|
| Technology | AC/DC Switching Adapter with USB Power Supply AC Adaptor |
|---|
| Category | ICT / ITE / Medical Power Supply |
|---|
| Input Voltage Range (V) | 100-240V~, 50/60Hz |
|---|
| Max Input Current (A) | 0.3A |
|---|
| Max Output Power Rating (W) | 10 |
|---|
| Output Voltage Range (V) | 5-5.2 |
|---|
| Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 |
|---|
| Ingress Protection | |
|---|
| Size (mm) | 60.0*41.2*48.9 +/-1.0 |
|---|
| Enclosure |
 |
|---|
| 3D File Download | https://www.globtek.com/file/dl/gtm86100-10vv-w2k-usb_asm.stp |
|---|
Rating Table |
|---|
| Model Number (Final ordering #/Part No to be defined) | Voltage (V) | Current (A) | Power (W) | RFQ |
|---|
* (Final ordering #/Part No to be defined) |
Specifications |
|---|
Input| Input Voltage: | Specified: 85-264VAC, Nameplate: 100-240VAC |
|---|
| Input Frequency: | Specified: 47-63Hz, Nameplate: 50-60Hz |
|---|
| No Load Input Power: | <75mW @ 230VAC (EU CoC Tier 2 compliant) |
|---|
| Inrush Current: | 30A @ 115VAC, 60A @ 230VAC typ. (at peak of AC line, cold start) |
|---|
| Efficiency: | 78.7% min. (CEC&DOE Level VI compliant), 79.0% min. (EU CoC Tier 2 compliant) |
|---|
Output| Turn-on Delay: | 3 seconds max. |
|---|
| Rise-Time: | 100ms max. |
|---|
| Output Regulation | ± 5% (measured at the end of a 1.2m long 20AWG USB cordset) |
|---|
| Ripple: | 100mV (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW) |
|---|
| Transient Response: | 10% max. deviation (with 25-75% load step), 1ms max. recovery time |
|---|
| Hold-up Time: | 5ms min. (100VAC and full load) |
|---|
Protections| Input Protection: | MOV transient suppressor, input line fusing |
|---|
| Over-Current Protection: | 110% to 150%, auto-restart |
|---|
| Over-Voltage Protection: | 10VDC max. (Zener clamp) |
|---|
| Short-Circuit Protection: | Auto-restart |
|---|
| Over-Temperature Protection: | Auto-restart, on-chip temperature sensor |
|---|
Environmental| MTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
|---|
| Operating Temperature: | 0°C to 40°C (full load) |
|---|
| Operating Humidity: | 20% to 85% relative humidity, non-condensing |
|---|
| Storage Conditions: | -20°C to 60°C / 5% to 95% relative humidity, non-condensing |
|---|
| Cooling: | Natural convection |
|---|
Safety| Certifications: | IEC60601-1 IEC60601-1-11 IEC62368-1 |
|---|
| Dielectric Withstand Voltage: | 4000VAC or 5656VDC (primary-to-secondary) 5mA, 1 minute |
|---|
| Output Touch Current: | NC: 100µA max. SFC: 500µA max. |
|---|
| Earth Leakage Current | N/A, Class II input (No protective earth pin, therefore earth leakage is not measured) |
|---|
| Means of Protection: | 2 x MOPP (primary-to-secondary) |
|---|
EMC| Certifications: | IEC60601-1-2 EN55032 (CISPR32) EN55035 (CISPR35) |
|---|
| Conducted Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
|---|
| Radiated Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
|---|
| Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
|---|
| Voltage Fluctuations/Flicker: | EN61000-3-3 |
|---|
| Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 8KV contact discharge, 15KV air discharge, Criterion A |
|---|
| Radiated RF Immunity: | EN61000-4-3, 10V/m (80MHz-2.7GHz), Table 9, 9-28V/m (385MHz-5.78GHz ), Criterion A |
|---|
| EFT/Burst Immunity: | EN61000-4-4, 2KV/100kHz., Criterion A |
|---|
| Line Surge Immunity: | EN61000-4-5, 2KV differential, Criterion A |
|---|
| Conducted RF Immunity: | EN61000-4-6, 3VRMS, 80% 1KHz AM, Criterion A |
|---|
| Power Frequency Magnetic Field Immunity: | EN61000-4-8, N/A |
|---|
| Voltage Dip Immunity: | EN61000-4-11, Criterion A/B |
|---|
Enclosure| Housing: | High impact plastic, PC+ABS 94V0, non-vented |
|---|
| Markings: | Laser marked or adhesive-backed label |
|---|
|
| Derating Curve |  |
|---|
| Qty (ea.)/Carton | 300 |
|---|
| Individual Box/Gift Box Size (mm) | 43(L)*30(W)*75 |
|---|
| Individual Box/Gift Box Color | 43(L)*30(W)*75 |
|---|
| Master Carton Size (mm) | 485 x 335 x 305 |
|---|
| Gross Weight (kg) | 12 |
|---|
| Label Width (mm) | 37.0 |
|---|
| Label Height (mm) | 19.0 |
|---|
Input Configuration |
|---|
| Description | UK BS 1363, 2 Blade w/Dummy Ground Class II The line and neutral pins have a rectangular cross section 6.35 mm by 4.0 mm, 17.7 mm long and with centres 22.2 mm apart. The protective-earth pin is a rectangular cross section 8.0 mm by 4.0 mm, 22.3 mm long and with a centre line 22.2 mm from the line/neutral pin centre line. The dimensions were originally specified in decimal inches with asymmetric tolerances and redefined as minimum and maximum metric dimensions in BS 1363:1984. Dimensions are chosen to provide safe clearance to live parts. The distance from any part of the line and neutral pins to the periphery of the plug base must be not less than 9.5 mm. This ensures that nothing can be inserted alongside a pin when the plug is in use, and helps keep fingers away from the pins. The minimum insertion distance from the face of the socket-outlet to the first point of contact with a live part is 9.6 mm. The "Dummy" longer earth pin ensures that the earth path is connected before the live pins, and remains connected after the live pins are removed. The earth pin is too large to be inserted into the line or neutral sockets by mistake.
 |
|---|
Output Configuration |
|---|
Common output connector options: Click to add to your request.
| 
| 
| 
| 
| 
| | L Type (Coaxial 5.5x2.5mm plug) | C Type (Coaxial 5.5x2.1mm plug) | K Type (Coaxial 3.5x1.3mm plug) | LL Type (5.5x2.5mm Locking 760k type) | CL Type (5.5x2.1mm Locking S761k type) | Magnetic Connector | 
| 
| 
| 
| 
| | YL3 Type (KPPX-3P) | YL4 Type (KPPX-4P) | EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) | MSB Type (Micro USB) | Inquire for custom design |
![]()
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions.
|