GTM91120CC-30VV-P2 | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GTM91120CC-30VV-P2, ICT / ITE / Medical Power Supply, Potted/Encapsulated in plastic housing, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: UKCA; CB EN/IEC 60335-1; CE; ETL; CB 60335; | ||||||||||||||||||||||||||||||||||||
Information | ||||||||||||||||||||||||||||||||||||
Model Number | GTM91120CC-30VV-P2 | |||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM91120-P2%20-P3/ | |||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0Oa000000HWY4KEAX | |||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0Oa000000HWY4KEAX | |||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000HWY4KEAX | |||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000HWY4KEAX | |||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | |||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | |||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | |||||||||||||||||||||||||||||||||||
Model Parameters | ||||||||||||||||||||||||||||||||||||
Type | Potted/Encapsulated in plastic housing | |||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | |||||||||||||||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply | |||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | |||||||||||||||||||||||||||||||||||
Max Input Current (A) | 1.5A | |||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 30 | |||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 5-48 | |||||||||||||||||||||||||||||||||||
Efficiency | V | |||||||||||||||||||||||||||||||||||
Ingress Protection | IP68 | |||||||||||||||||||||||||||||||||||
Size (mm) | 102*46*37 | |||||||||||||||||||||||||||||||||||
Enclosure | ||||||||||||||||||||||||||||||||||||
Rating Table | ||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | ||||||||||||||||||||||||||||||||||||
Specifications | ||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 1. Input Voltage: 100-240 Vac 2. Input Frequency: 47 - 63 Hz 3. Output power (rated): 15Watts max, Constant Current 4. Output Regulation: +/- 5% measured at the output connector 5. Line Voltage Regulation: +/- 2% typical measured at full load 6. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector at nominal line 7. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load 8. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line 9. Hold-Up Time: 5mS typical @ nominal input voltage and full load 10. Inrush Current: 60A maximum cold start @ 240Vac input 11. Switching Frequency: 100 KHz typical B) PROTECTION 1. Over-Voltage: Protected with a Zener diode clamp across the output 2. Short Circuit: Hiccup with auto recovery 3. Over-load: Hiccup with auto recovery 4. Input Protection: Input line and neutral fusing C) SAFETY 1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary 2. Earth Leakage Current: <100 uA at 240Vac input voltage D) OTHER: 1. MTBF: 200,000 Hours @ 25°C ambient temperature 2. Operating Temperature: 0°C to 40°C ambient temperature 3. Humidity: 0% to 90% relative humidity 4. Storage Temperature: -10°C to 80°C 5. Cooling: Convection 6. For EMI suppression 28A026-0A2 Snap-on Ferrites are recommended on both input and output cables, if required. E) ENCLOSURE 1. Housing: High impact plastic, 94V0 polycarbonate, non-vented 2. Size: 43.5 x 74.0 x 35.3 mm +/-1.0 mm 3. Markings: Label and/or Pad Printed and/or Molded in the case | ||||||||||||||||||||||||||||||||||||
Derating Curve | ||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | ||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | ||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | ||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | TBD | |||||||||||||||||||||||||||||||||||
Gross Weight (kg) | ||||||||||||||||||||||||||||||||||||
Label Width (mm) | ||||||||||||||||||||||||||||||||||||
Label Height (mm) | ||||||||||||||||||||||||||||||||||||
Input Configuration | ||||||||||||||||||||||||||||||||||||
Description | See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths. | |||||||||||||||||||||||||||||||||||
Output Configuration | ||||||||||||||||||||||||||||||||||||
Common output connector options: Click to add to your request.
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. |