GTM962254PWWWVVX-XF GTM962254PWWWVVX-XF, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/ L Frame/Cage/ Potted Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140W, 12-54V in 0.1V increments, Approvals: CB 60601-1 (pending); CE; China RoHS; UKCA; Morocco; EAC; WEEE; VCCI; Ukraine; Level VI; RoHS; cRUus (pending); Information
Model Number GTM962254PWWWVVX-XF Agency Documents http://www.globtek.info/certs/GTM96225xP%20/ CE EC-Declaration for Medical https://cs.globtek.info/ec_declaration?id=a0O3a00000MljATEAZ CE EC-Declaration for Industrial/Commercial/ITE https://cs.globtek.info/ec_declaration?id=a0O3a00000MljATEAZ CE EC-Declaration for Household Contact GlobTek for more information UKCA-Declaration for Medical https://cs.globtek.info/ukca_declaration?id=a0O3a00000MljATEAZ UKCA-Declaration for Industrial/Commercial/ITE https://cs.globtek.info/ukca_declaration?id=a0O3a00000MljATEAZ UKCA-Declaration for Household Contact GlobTek for more information Morocco SDoC Declaration https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O3a00000MljATEAZ RoHS/RoHS3 Declaration https://www.globtek.com/pdf/rohs_cert/a0O3a00000MljATEAZ Prop 65 Statement https://www.globtek.com/r2/PH7CNf REACH Declaration https://www.globtek.com/r2/eM2co8 Conflict Minerals Declaration https://www.globtek.com/r2/vZY8R5 Model Parameters
Type Open Frame/ L Frame/Cage/ Potted Internal Technology Regulated Switchmode AC-DC Power Supply AC Adaptor Category ICT / ITE / Medical Power Supply Input Voltage Range (V) 100-240V~, 50-60 Hz Max Input Current (A) 3A Max Output Power Rating (W) 225 Output Voltage Range (V) 12-54 Auxiliary/Fan Output Voltage (V) Auxiliary/Fan Output Power (W) Efficiency USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 Ingress Protection N/A Size (mm) 101.6 (L) x 50.8 (W) x 31.0 (H) Enclosure 3D File Download https://www.globtek.com/dl/GTM962250PWWWVVX-XF.igs Rating Table
Model Number (Final ordering #/Part No to be defined) Voltage (V) Current (A) Power (W) RFQ GTM962254P13024B-EF* 24 5 120 RFQ
* (Final ordering #/Part No to be defined)
Specifications
Input Input Voltage: Specified: 85-264VAC, Nameplate: 100-240VAC Input Frequency: Specified: 47-63Hz, Nameplate: 50-60Hz Input Current: 2.75A typ. @ 85VAC, 1.0A typ. @ 230VAC (full load) No Load Input Power: < 500mW Inrush Current: < 75A @ 230VAC (cold start @ 25°C) Efficiency: 90 - 95% typ. (full load) Power Factor: >0.90 @ 115VAC, >0.85 @ 230VAC, full load
Output Turn-on Delay: < 1 second @ 85VAC Line Regulation: ± 0.5% (measured at connector) Startup Overshoot: < 5% (full load) Transient Response: < 5% deviation (with 25% load step), recovery to within 1% in 1ms Hold-Up Time: 10ms min. (full load) Output Indicator: Green LED
Main Output Output Power: 120W Output Regulation: ± 1.0% (measured at connector) Ripple: < 1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Auxiliary Output Output Power: 10W Output Regulation: - 1.0% / + 5% (measured at connector) Ripple: < 100mVpk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Protections Input Protection: MOV transient suppressor, dual fuses (line + neutral) Over-Voltage Protection: 110-130% of main output. Latched-off, cycle AC to reset Over-Current Protection: Main output: 140% typical, auto-recovery Auxiliary output: 110 - 215%, auto-recovery Short Circuit Protection: Non-latched with auto-recovery Over-Temperature Protection: NTC temperature sensor embedded in transformer, trip between 115 - 120°, latched-off, cycle AC to reset (auto-recovery available as special option)
Environmental MTBF: 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) Operating Temperature: -20°C to 50°C (full output power), -25°C to 80°C (derated) Storage Temperature: -30°C to 85°C Humidity: 0% to 95% relative humidity, non-condensing Altitude: 5000m max. Vibration: Conforms to EN60068-2-6, ISO80601-2, EN1789
Safety Dielectric Withstand Voltage: 4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth Intended Medical Application: Type-B or Type-BF Touch Current: 3-conductor input - NC: <25µA, SFC: <200µA 2-conductor input - NC: <65µA, SFC: <140µA Earth Leakage Current 3-conductor input: <200µA 2-conductor input: N/A Means of Protection: 2 x MOPP Primary-Secondary Bridging Capacitance: Two IEC60384-14 certified Y1 capacitors in series
EMC Applicable Standards: Medical: EN60601-1-2, 4th edition Emissions: EN55032, EN 55011, EN61000-6-3, EN61000-6-4, CISPR11/CISPR22 Immunity: EN55024, EN61000-6-1, EN61000-6-2 Conducted Emissions: Class B, FCC Part 15, Class B (with resistive load) Radiated Emissions: Class B, FCC Part 15, Class B (with resistive load) Harmonic Current Voltage Distortion: EN61000-3-2, Class A Voltage Fluctuations/Flicker: EN61000-3-3 Electrostatic Discharge (ESD) Immunity: EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input or output terminals) Radiated RF Immunity: EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM EFT/Burst Immunity: EN61000-4-4, 4KV/100kHz. Line Surge Immunity: EN61000-4-5, 2KV differential, 4KV common-mode Conducted RF Immunity: EN61000-4-6, 3VRMS, (6VRMS in ISM/amateur bands), 80% 1KHz AM Power Frequency Magnetic Field Immunity: EN61000-4-8, 30A/m Voltage Dip Immunity: EN61000-4-11
Special Options Custom labels/markings Short term output surge capability Reduced touch current Reduced output ripple Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3 IEC61000-3-2 Class-C line harmonics for LED lighting applications Non-latching (auto-recover) over-temperature protection Potentiometer to adjust/trim output voltage Derating Curve Qty (ea.)/Carton 20 Individual Box/Gift Box Size (mm) Cellular Packag Individual Box/Gift Box Color Cellular Packag Master Carton Size (mm) 450 x 461 x 182 Gross Weight (kg) 8.68 Label Width (mm) TBD Label Height (mm) TBD Input Configuration
Description Optional Input Wiring Kits are available:Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.Approvals Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.