GTM91110P150VV-F-S Open Frame/Internal ICT / ITE / Medical Power Supply
GTM91110P150VV-F-S | ||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GTM91110P150VV-F-S, ICT / ITE / Medical Power Supply, Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral, Output Rating: 150 Watts, Power rating with convection cooling (W) , 12-55V in 0.1V increments, Approvals: EAC; cETLus; Book 60601; CB 60601-1; CB 60950; CE; CE; cETLus 60601-1 3rd; China RoHS; Class I; FCC; RoHS; SIQ; SIQ; Ukraine; VCCI; WEEE; cETLus; | ||||||||||||||||||||||||||||||||||||||||||||||
Information | ||||||||||||||||||||||||||||||||||||||||||||||
Model Number | GTM91110P150VV-F-S | |||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM91110P/ | |||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | |||||||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0Oa000000MEMMcEAP | |||||||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | |||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | |||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | |||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | ||||||||||||||||||||||||||||||||||||||||||||||
Type | Open Frame/Internal | |||||||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | |||||||||||||||||||||||||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply | |||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | |||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 4.0A | |||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 150 | |||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 12-55 | |||||||||||||||||||||||||||||||||||||||||||||
Efficiency | N/A | |||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | ||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 127x76.2x43 1U | |||||||||||||||||||||||||||||||||||||||||||||
Enclosure | Label 1 Position Label 1 on top of Transformer Label 2 Material: White art paper with Black nomenclature and is attached on top of CX1 Label 3 Material: White art paper with Black nomenclature and is attached on side of CX1 | |||||||||||||||||||||||||||||||||||||||||||||
Rating Table | ||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | ||||||||||||||||||||||||||||||||||||||||||||||
Specifications | ||||||||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated 100-240 Vac 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60 Hz 03. Inrush current: Cold start @ 25°C, 40A @ 115Vac, 80A @ 230Vac 04. Efficiency: 85% to 90% typical at full load, 120-240Vac input 05. Power factor: 0.98 typical at full load, 230Vac input 06. Turn on delay: 5 Seconds maximum, (3 seconds max option) 07. Load regulation: ± 1% Measured at the connector side 08. Line regulation: ± 0.2% Measured at the connector side 09. Output Ripple protection (Peak to Peak): +/-1% maximum of nominal output voltage measured at 20 MHz bandwidth with 0.1µf ceramic capacitor in parallel with a low impedance 47 µf electrolytic capacitor located 200mm from the end of the output connector 10. Turn on/off overshoot: 5% Maximum, 1mS recovery time 11. Hold up time: 8 mS @ 300W load, 10mS@200W load, 16mS@150W load at 115Vac input 12. Transient response: 2% Maximum deviation, returns to initial condition in 3 ms max for 25% load step, from 10% to 100% of rated load 13. Remote sense (optional): compensates for up to 0.5V voltage drop in output wiring. Power supply will operate correctly, with or without remote sense pins hooked up. 14. Auxillary Output: For forced air fan 12V @ 250mA, if convection cooled 12V @ 150mA. Other output voltages and current ratings from 5V to 24V available, contact factory for availability. 15. Indicator: Green LED for output presence B) PROTECTION 01. Input Protection: Input line fusing and 300Vac MOV 02. Short circuit: Protected. Unit will autorecover upon removal of short 03. Overload protection: Autorecover upon removal of overload 150W, 175% - 210% of nominal power rating 200W, 130% - 160% of nominal power rating 240W, 110% - 130% of nominal power rating 300W, 110% - 130% of nominal power rating 04. Over voltage: Protected at 110- 140% of nominal output voltage, latched type. AC cycling required to restore output. Autorecovery type OVP is an option, contact factory for availability. 05. Fan output protection: 3 Pin Linear Regulator, short circuit proof C) SAFETY 01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output, On Class I models, 2500Vac or 3535Vdc from input to earth 02. Earth Leakage Current: Class I Input Models: Does not exceed 500uA Class II Input Models: Does not apply 03. Touch Current: Does not exceed 100uA, output terminations to earth 04. Output terminations rated as SELV, and Means of Operator Protection D) OTHER: 01. MTBF: 200,000 Hours @ 25°C ambient temperature 02. Operating Temperature Range: -10°C to 50°C @ 100% output power rating -10°C to 70°C @ 50% output power derating 03. Cooling: Open Frame 150W Series: Convection Open Frame 240W and 300W Series: 20 CFM Forced Air Cooling Perforated Plastic Housing 200W Series: 20 CFM Forced Air Cooling, with convection cooling 50% derated (100W) output capability. 04. Relative Humidity: operating 0% to 90% Non-condensing 05. Storage Temperature: -30°C to 85°C 06. Altitude: up to 2000 meter 07. Random vibration/transient drop: MIL-STD 810E E) MECHANICAL FORMAT: 150W, 240W and 300W Open Frame version Size: 127*76.2*43 mm Weight: 470 grams 200W Perforated Plastic Enclosure version Size: 140*87.6*51.9 mm Weight: 620 grams | ||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | ||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 60 | |||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | 135*85*60 | |||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | White | |||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 430 x 380 x 275 | |||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 14.0 | |||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | 30.0 | |||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | 20.0 | |||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | ||||||||||||||||||||||||||||||||||||||||||||||
Description | Molex 26-60-4030 3 Position Header Pin 1: Line, Pin 2: Removed, PIN 3: Neutral Optional Input Wiring Kits are available:
| |||||||||||||||||||||||||||||||||||||||||||||
Approvals | ||||||||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | ||||||||||||||||||||||||||||||||||||||||||||||
|