GTM962500PWWWVV.V-CX Open Frame/Internal ICT / ITE / Medical Power Supply
GTM962500PWWWVV.V-CX | |||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
GTM962500PWWWVV.V-CX, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, 3 Positon Terminal Block, Output Rating: 250 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: PSE; PSE; PSE; CE; RoHS; China RoHS; Ukraine; WEEE; VCCI; Level VI; EAC; UKCA; CCC (pending); CB 60950 (pending); CB 60601-1 (pending); cETLus UL1310 (pending); ETL (pending); CB 62368 (pending); ETL 62368 (pending); CB 60335 (pending); CB 61347 (pending); Morocco; | |||||||||||||||||||||||||||||||||||||||||||||||||
Information | |||||||||||||||||||||||||||||||||||||||||||||||||
Model Number | GTM962500PWWWVV.V-CX | ||||||||||||||||||||||||||||||||||||||||||||||||
Agency Documents | http://www.globtek.info/certs/GTM962400P/ | ||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0O0c00000PHWgzEAH | ||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0O0c00000PHWgzEAH | ||||||||||||||||||||||||||||||||||||||||||||||||
CE EC-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0O0c00000PHWgzEAH | ||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0O0c00000PHWgzEAH | ||||||||||||||||||||||||||||||||||||||||||||||||
UKCA-Declaration for Household | Contact GlobTek for more information | ||||||||||||||||||||||||||||||||||||||||||||||||
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O0c00000PHWgzEAH | ||||||||||||||||||||||||||||||||||||||||||||||||
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O0c00000PHWgzEAH | ||||||||||||||||||||||||||||||||||||||||||||||||
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf | ||||||||||||||||||||||||||||||||||||||||||||||||
REACH Declaration | https://www.globtek.com/r2/eM2co8 | ||||||||||||||||||||||||||||||||||||||||||||||||
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 | ||||||||||||||||||||||||||||||||||||||||||||||||
Model Parameters | |||||||||||||||||||||||||||||||||||||||||||||||||
Type | Open Frame/Internal | ||||||||||||||||||||||||||||||||||||||||||||||||
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor | ||||||||||||||||||||||||||||||||||||||||||||||||
Category | ICT / ITE / Medical Power Supply | ||||||||||||||||||||||||||||||||||||||||||||||||
Input Voltage Range (V) | 100-240V~, 50-60 Hz | ||||||||||||||||||||||||||||||||||||||||||||||||
Max Input Current (A) | 1.8 A | ||||||||||||||||||||||||||||||||||||||||||||||||
Max Output Power Rating (W) | 250 | ||||||||||||||||||||||||||||||||||||||||||||||||
Output Voltage Range (V) | 12-54 | ||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 | ||||||||||||||||||||||||||||||||||||||||||||||||
Ingress Protection | na | ||||||||||||||||||||||||||||||||||||||||||||||||
Size (mm) | 203*63.5*41 | ||||||||||||||||||||||||||||||||||||||||||||||||
Enclosure | |||||||||||||||||||||||||||||||||||||||||||||||||
3D File Download | https://www.globtek.com/file/dl/GTM962500PWWWVV.V-CX.zip | ||||||||||||||||||||||||||||||||||||||||||||||||
Rating Table | |||||||||||||||||||||||||||||||||||||||||||||||||
* (Final ordering #/Part No to be defined) | |||||||||||||||||||||||||||||||||||||||||||||||||
Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||
A) ELECTRICAL SPECIFICATIONS: 01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac 90-264Vac range @ 100% of rated load current 85-264 Vac range @ 90% of rated load current 02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz 03. Power Factor: 0.90 minimum @ 230Vac, 0.97 minimum @ 115Vac 04. Output Regulation: +/- 4% measured at the output connector 05. Line Voltage Regulation: +/- 0.5% typical measured at full load 06. Green Power On Indicator LED 07. Output Ripple (Vp-p): 1% or 200 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uF electrolytic capacitor connected at the end of the output connector at nominal line 08. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load 09. Turn-ON Delay: 1 second typical 10. Hold-Up Time: 20 mS minimum 11. Inrush Current: 30A maximum at 115Vac input and 60A maximum at 230Vac input 12. Switching Frequency: Varies from 30KHz to 133KHz 13. Efficiency: > 90% 14. No Load Standby Power: <0.15 W @ 230Vac B) PROTECTION 01. Input Protection: Input line fusing and 300Vac rated MOV 02. Short Circuit/ Overload: Electronically Protected unit will auto recover upon removal of fault Output Current Limit: Current limited to less than 330W / Vnom (Vnom = nominal rated output voltage) 03. Over-Temperature: Latching Electronic Overtemperature protection. Cycle AC OFF to reset. 04. Output Over-Voltage: 110% to 135% of nominal output voltage under full load condition, and less than 60V max. Latching protection, cycle AC OFF to reset. C) SAFETY 01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output, On Class I models, 3000Vac or 4242Vdc from input to earth 02. Earth Leakage Current: Class I models < 300uA, N/A for Class II models 03. Touch Current: Class I models < 20uA, Class II models < 70uA 04. Output Isolation Options: a) C8 or C18 Inlet, Class II b) C6 or C14 Inlet, Class II FE, Output Isolated from Earth contact c) C6 or C14 Inlet, Class I, Output negative directly attached to Earth contact 05. Earth Continuity Test: < 0.1 Ohm between Earth Pin at AC input and PCB termination point (Class I models only) 06. Means of Protection: 2 x MOPP 07. Primary to Secondary Bridging Capacitance: Two IEC60384-14 certified Y1 type capacitors in series 08. Compliant Standards: See listings at end of this drawing for specifics D) EMC EN 60601-1-2, 4th edition Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4 Conducted Emissions: Class B, FCC Part 15, Class B Radiated Emissions: Class B, FCC Part 15, Class B Line Frequency Harmonics EN61000-3-2, Class A Voltage Fluctuations/Flicker EN61000-3-3 Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2 Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 18kV air discharge Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM. EFT/Burst Immunity EN61000-4-4, 4kV/100kHz. Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m Voltage Dip Immunity EN61000-4-11, Criteria E) OTHER: 01. MTBF: 500,000 Hours @ 50°C ambient temperature, Full Load 02. Operating Temperature: -10°C to 50°C ambient temperature with full load Regarding Operating Temperature, a- See below derating table for output power capability at alternate temperature b- Extended low end temperature range down to -40°C available as a custom option c- Power rating based upon 10CFM forced air flow 03. Humidity: 0% to 95% relative humidity, non-condensing 04. Storage Temperature: -30°C to 80°C 05. ROHS: Compliant with latest regulations, see approvals section below 06. Operational Altitude: 5000M F) MECHANICAL 01. Open Frame configuration, standard option 02. L Chassis configuration, alternate option, may be purchase separately 03. Cage Configuration, alternate option, may be purchased separately 04. Alternate input and output connector options (see diagram), terminal block is standard a- Terminal Block, screws face up: T762-01-3P Input, T762-01-4P Output, TIANLI b- Terminal Block, screws from side: T762-03-3P Input, T762-03-4P Output, TIANLI c- Push to Engage Header: A7920W-3P Input, A7920W-40 Output, MOLEX G) SPECIAL OPTIONS 01. Custom connector types 02. Custom Markings 03. Short term Output Surge Power Capability 04. Reduced Leakage Current version, medical CF leakage current compliance 05. Tightened output voltage tolerance 06. Reduced Output Ripple Level 08. Reduced output power marking/rating 09. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance 10. LED Lighting Applications, Class C Line Harmonics 11. Constant Current output, for Vnom to 0.75xVnom. Add “-CC” suffix to model number. Current level is custom selectable. | |||||||||||||||||||||||||||||||||||||||||||||||||
Derating Curve | |||||||||||||||||||||||||||||||||||||||||||||||||
Qty (ea.)/Carton | 20 | ||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Size (mm) | Cellular Packag | ||||||||||||||||||||||||||||||||||||||||||||||||
Individual Box/Gift Box Color | |||||||||||||||||||||||||||||||||||||||||||||||||
Master Carton Size (mm) | 450 x 461 x 182 | ||||||||||||||||||||||||||||||||||||||||||||||||
Gross Weight (kg) | 16 | ||||||||||||||||||||||||||||||||||||||||||||||||
Label Width (mm) | TBD | ||||||||||||||||||||||||||||||||||||||||||||||||
Label Height (mm) | TBD | ||||||||||||||||||||||||||||||||||||||||||||||||
Input Configuration | |||||||||||||||||||||||||||||||||||||||||||||||||
Description | 3 Positon Terminal Block Optional Input Wiring Kits are available:
| ||||||||||||||||||||||||||||||||||||||||||||||||
Approvals | |||||||||||||||||||||||||||||||||||||||||||||||||
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. | |||||||||||||||||||||||||||||||||||||||||||||||||
|