GTM96600-65VV.V-P3 |
---|
| GTM96600-65VV.V-P3, ICT / ITE / Medical Power Supply/Class 2/Household Power Supply, 60601-1-4th Ed. , Potted/Encapsulated in plastic housing, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60Hz, See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 65 Watts, Power rating with convection cooling (W) , 5-54V in 0.1V increments, Approvals: IP68; cETLus 60601-1; CB 62368; RCM; LPS 60950; WEEE; VCCI; Ukraine; Level VI; PSE; PSE; PSE; China RoHS; CE; CB 60950; EAC; UKCA; CB 61158; S-Mark IEC/EN 60601-1; UL 1310; Morocco; |
---|
Information |
---|
Model Number | GTM96600-65VV.V-P3 |
---|
Agency Documents | http://www.globtek.info/certs/GTM96600-TZ/ |
---|
CE EC-Declaration for Medical | https://cs.globtek.info/ec_declaration?id=a0O0c00000PHQDbEAP |
---|
CE EC-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ec_declaration?id=a0O0c00000PHQDbEAP |
---|
CE EC-Declaration for Household | https://cs.globtek.info/ec_declaration?id=a0O0c00000PHQDbEAP |
---|
UKCA-Declaration for Medical | https://cs.globtek.info/ukca_declaration?id=a0O0c00000PHQDbEAP |
---|
UKCA-Declaration for Industrial/Commercial/ITE | https://cs.globtek.info/ukca_declaration?id=a0O0c00000PHQDbEAP |
---|
UKCA-Declaration for Household | https://cs.globtek.info/ukca_declaration?id=a0O0c00000PHQDbEAP |
---|
Morocco SDoC Declaration | https://cs.globtek.info/Morocco_SDoC_Declaration?id=a0O0c00000PHQDbEAP |
---|
RoHS/RoHS3 Declaration | https://www.globtek.com/pdf/rohs_cert/a0O0c00000PHQDbEAP |
---|
Prop 65 Statement | https://www.globtek.com/r2/PH7CNf |
---|
REACH Declaration | https://www.globtek.com/r2/eM2co8 |
---|
Conflict Minerals Declaration | https://www.globtek.com/r2/vZY8R5 |
---|
Model Parameters |
---|
Type | Potted/Encapsulated in plastic housing |
---|
Technology | Regulated Switchmode AC-DC Power Supply AC Adaptor |
---|
Category | ICT / ITE / Medical Power Supply/Class 2/Household Power Supply |
---|
Input Voltage Range (V) | 100-240V~, 50-60Hz |
---|
Max Input Current (A) | 1.5A |
---|
Max Output Power Rating (W) | 65 |
---|
Output Voltage Range (V) | 5-54 |
---|
Efficiency | USA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782 |
---|
Ingress Protection | IP68 |
---|
Size (mm) | 114.81*57.11*39.00 |
---|
Enclosure |
|
---|
3D File Download | https://www.globtek.com/dl/GTM96600-6512-P3.stp |
---|
Rating Table |
---|
Model Number (Final ordering #/Part No to be defined) | Output Number | Voltage | Amps (Convection) | Amps (Forced Air) | Watts (Convection) | Watts (Forced Air) | RFQ |
---|
* (Final ordering #/Part No to be defined) |
Specifications |
---|
InputInput Voltage: | Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 85% rated load current for 85-264VAC 100% rated load current for 110-370VDC |
---|
Input Frequency: | Specified: 47-63Hz, Nameplate: 50-60Hz |
---|
No Load Input Power: | <75mW @ 230VAC (EU CoC Tier 2 compliant) for ≤ 49W rating <150mW @ 230VAC (EU CoC Tier 2 compliant) for > 49W rating |
---|
Inrush Current: | 30A/60A max. (cold start @ 115V/230VAC) |
---|
Efficiency: | DoE Level VI and EU CoC Tier 2 compliant |
---|
OutputTurn-on Delay: | 1 second max. @ 115VAC and full load |
---|
Output Regulation: | ± 5% (measured at output connector) |
---|
Line Regulation: | ± 0.5% typ. (measured at output connector) |
---|
Ripple: | 1% or 100mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector) |
---|
Transient Response: | 5% max. deviation, 1ms typ. recovery time (with 40% to 70% load step) |
---|
Hold-up Time: | 8ms typ. (nominal input voltage and full load) |
---|
Power Indicator: | Green LED |
---|
ProtectionsInput Protection: | MOV transient suppressor, input line fusing |
---|
Over-Current Protection: | 110 - 160% of rated output current, auto-restart, current limit range determined by normal output power rating, not de-rated power rating |
---|
Short-Circuit Protection: | Auto-restart |
---|
Over-Voltage Protection: | 110 - 130%, latched off, cycle AC to reset |
---|
Over-Temperature Protection: | On-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~140°C, latched off, cycle AC to reset |
---|
EnvironmentalMTBF: | 1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3) |
---|
Operating Temperature: | -20°C to 40°C (full load) |
---|
Storage Temperature: | -30°C to 80°C |
---|
Humidity: | 0% to 95% relative humidity, non-condensing |
---|
Altitude: | 5000m |
---|
Cooling: | Convection |
---|
RoHS: | Complies with EU 2011/65/EU and China SJ/T 11363-2006 |
---|
Note 1: | Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option |
---|
SafetyDielectric Withstand Voltage: | 4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only) |
---|
Touch Current: | Class I: 20µA max. Class II: 85µA max. Class II F2: 20µA max. |
---|
Earth Leakage Current | Class I: 300µA max. Class II: N/A |
---|
Means of Protection: | 2 x MOPP |
---|
Output Isolation Options: | Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity. |
---|
Earth Continuity Test: | < 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only) |
---|
Compliant Standards: | See listing at end of this datasheet for specific standards |
---|
EMCApplicable Standards: | Medical: EN60601-1-2, 4th edition Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22 Immunity: EN55024, EN61000-6-1, EN61000-6-2 |
---|
Conducted Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
---|
Radiated Emissions: | Class B, FCC Part 15, Class B (with resistive load) |
---|
Harmonic Current Voltage Distortion: | EN61000-3-2, Class A |
---|
Voltage Fluctuations/Flicker: | EN61000-3-3 |
---|
Electrostatic Discharge (ESD) Immunity: | EN61000-4-2, 10KV contact discharge, 20KV air discharge |
---|
Radiated RF Immunity: | EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM |
---|
EFT/Burst Immunity: | EN61000-4-4, 4KV/100kHz. |
---|
Line Surge Immunity: | EN61000-4-5, 2KV differential, 4KV common-mode |
---|
Conducted RF Immunity: | EN61000-4-6, 3VRMS, 80% 1KHz AM |
---|
Power Frequency Magnetic Field Immunity: | EN61000-4-8, 3A/m |
---|
Voltage Dip Immunity: | EN61000-4-11 |
---|
EnclosureHousing: | High impact plastic, 94V0 polycarbonate, non-vented |
---|
AC Input Mechanical Options: | Desktop: C6, C7, C14, or C18 inlet Hybrid: Desktop inlet or changeable blades for wall-plug-in style, Class I or Class II input |
---|
Markings: | Label and/or pad printed and/or laser-etched into case |
---|
Special Options- Removal of LED (cost reduction or aesthetic purpose)
- Custom cordsets, various cordage types, and connector types
- Custom markings
- Short term output surge capability for motors or other high peak current loads. (Available up to 120W for 1 second at nameplate voltage range. Higher levels possible for limited input voltage range, or larger allowed voltage dip.)
- Reduced leakage current
- Tightened output voltage tolerance
- Reduced output ripple level
- Reduced output power rating
- High reliability PCB laminate with plated through-holes for IPC610 Class 2 compliance
- Low temperature option, down to -40°C
- Special housing and cordset colors
- "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
- Improved ingress protection (IP) rating
Output Connectors |
Derating Curve | |
---|
Qty (ea.)/Carton | 20 |
---|
Individual Box/Gift Box Size (mm) | Egg Crate |
---|
Individual Box/Gift Box Color | |
---|
Master Carton Size (mm) | 427 x 405 x 158 |
---|
Gross Weight (kg) | 15.6 |
---|
Label Width (mm) | 35.0 |
---|
Label Height (mm) | 70.0 |
---|
Input Configuration |
---|
Description | See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths.
|
---|
Output Configuration |
---|
Common output connector options: Click to add to your request.
|
|
|
|
|
| L Type (Coaxial 5.5x2.5mm plug) | C Type (Coaxial 5.5x2.1mm plug) | K Type (Coaxial 3.5x1.3mm plug) | LL Type (5.5x2.5mm Locking 760k type) | CL Type (5.5x2.1mm Locking S761k type) | Magnetic Connector |
|
|
|
|
| YL3 Type (KPPX-3P) | YL4 Type (KPPX-4P) | EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) | MSB Type (Micro USB) | Inquire for custom design |
Comprehensive list of GlobTek output cordset options Contact GlobTek for your specific requirements or custom solutions. |
Approvals |
---|
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice. Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation. |
Logo | Description |
---|
Medical 4th Ed. | EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info) | | Medical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance [AAMI ES60601-1:2005 +A1] | | JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb | No Logo Applicable | CB for IEC 60950-1:2005+A1+A2 | LPS | Limited Power Source 60950 | | UKCA Certification | | Japan: Voluntary Control Council for Interference (VCCI) | | JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb | | UL1310 Warning Label Up To 36 Volts with plugs | | CHINA SJ/T 11364-2014, China RoHS Chart: http://www.globtek.com/pdf/F-GT-DJD-8.4.1-006%20China%20RoHS%20Declaration%205-20-22.pdf | No Logo Applicable | IEC 61558-1:2005+A1, IEC 61558-2-16:2009+A1 | | JAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: https://www.globtek.com/r2/Szj4Vb | | Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe) | | Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration | | Test standard: EN 55032:2012+AC:2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015 | | Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/ | IP68 | Ingress Protection: ?IP68 to IEC60529:2001 Totally dust tight and Protected against long periods of immersion under pressure | No Logo Applicable | CB for IEC 62368-1:2014 (Second Edition) | | Ukraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf) | | WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case | GMA-513607-EA | RCM certificate ; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm | | S-Mark Certificate EN 60601-1:2006+A1+A12, EN 60601-1-11:2015 |
|