| NYLON JACKET PVC WIRE |
| UL |
SIZE |
RATING |
| T |
14 AWG-2000
MCM |
60°C 600V |
| TW |
14-2000 |
60°C 600V |
| THW |
14-2000 |
75°C 600V |
| THWN |
14-1000 Nylon |
75°C 600V |
| THHN |
14-1000 Nylon |
90°C 600V |
| TFN |
18-16 Nylon |
90°C 600V |
| TFFN |
18-16 Nylon |
90°C 600V |
| MTW |
22-1000 Nylon |
60°C 600V
90°C |
|
|
|
| 1008 |
28-16 Nylon |
80°C 600V |
| 1009 |
28-16 Nylon |
90°C 600V |
| 1010 |
28-16 Nylon |
105°C 600V |
| 1012 |
28-9 Nylon |
80°C 600V |
| 1016 |
28-9 Nylon |
105°C 600V |
| 1018 |
8-6 Nylon |
80°C 600V |
| 1025 |
8-6 Nylon |
90°C 600V |
| 1029 |
8-6 Nylon |
105°C 600V |
| 1316 |
26-12 Nylon |
105°C 600V |
| 1317 |
10 AWG Nylon |
105°C 600V |
| 1318 |
8-6 Nylon |
105°C 600V |
| 1319 |
4-2 Nylon |
105°C 600V |
| 1320 |
1-4/0 Nylon |
105°C 600V |
| 1321 |
250-500 Nylon |
105°C 600V |
1335
1340 |
22-1000 Nylon |
90°C 600V |
1342
1346 |
14-2 Nylon |
105°C 600V |
1408
1414 |
14-2 Nylon |
105°C 600V |
|
| RUBBER INSULATION WIRE |
| UL/CSA |
SIZE AWG. |
RATING |
| HPN/HPN |
18-12 AWG |
90°C 300V
105°C |
| HPD/HPD |
18-12 |
90°C 300V
105°C |
| HS |
14-12
(2c,3c,4c) |
60°C 300V
105°C |
| HSJ |
18-12
(2c,3c,4c) |
60°C 300V
105°C |
| HSO |
14-12
(2c,3c,4c) |
60°C 300V
105°C |
| HSJO |
18-12
(2c,3c,4c) |
60°C 300V
105°C |
| S |
18-2
(2c or more) |
60°C 600V
105°C |
| SO |
18-2
(2c or more) |
60°C 600V
105°C |
| SOO |
18-2
(2c or more) |
60°C 600V
105°C |
| SJ* |
18-10
(2-5C) |
60°C 300V
105°C |
| SJO* |
18-10
(2-5C) |
60°C 300V
105°C |
| SJOO* |
18-10
(2-5C) |
60°C 300V
105°C |
* The cord may be marked as water-
resistant, for outdoor use marked "W-A". |
| SILICONE WIRE |
| UL |
SIZE |
RATING |
| SF-1 |
18 |
200°C 300V |
| SF-2 |
18-14 |
200°C 600V |
| SFF-1 |
18 |
150°C 300V |
| SFF-2 |
18-14 |
150°C 300V |
|
| SIZE |
PE Thick. |
Nylon Thick. |
Nom. Diam. |
Length mil |
| 7/0.28mm x 1P |
0.4mm |
0.2mm |
4.1mm |
1 |
|
| COMPUTER CABLE |
| UL/CSA |
SIZE |
RATING |
| 2464/AWM |
29-9 AWG |
80°C 300V |
| 2343 |
min 30 |
80°C |
| 2384 |
min 40 |
60°C 300V |
| 2448 |
min 40 |
60°C 300V |
| 2919 |
min 40 |
|
| 20197 |
36-16
(2-50C) |
60°C 300V |
| 20187 |
33-18
(2-10C) |
80°C 300V |
|
| SHIELDED WIRE |
| UL/CSA |
SIZE |
RATING |
| 1061/AWM |
30-16 AWG |
80°C 300V |
| 1185/AWM |
30-16 |
80°C 300V |
| 1195 |
30-14 |
80°C 300V |
| 1208 |
30-16 |
80°C 150V |
| 1503 |
26-20 |
80°C |
| 1533/AWM |
30-16 |
80°C 300V |
| 1777 |
30-16 |
80°C 300V |
| 2547 |
30-16 |
80°C |
| 2854 |
40-24 |
80°C 300V |
|
| COMMUNICATION CABLE |
| CONDUCTOR |
PVC THICK
(INS.) |
PVC THICK
(JACKET) |
NOM. DIAM. |
MAX. DIAM.
(JACKET) |
| mm |
c |
mm |
mm |
mm |
mm |
| 0.5 |
6
12
22 |
0.3
0.3
0.3 |
0.9
0.9
0.9 |
6.5
8.0
10.0 |
7.5
9.0
11.0 |
24
33
40 |
0.3
0.3
0.3 |
0.9
0.9
0.9 |
10.0
11.5
12.0 |
11.0
12.5
13.0 |
48
60
75 |
0.3
0.3
0.3 |
0.9
0.9
0.9 |
12.5
14.0
15.5 |
13.5
15.0
16.5 |
80
100
120 |
0.3
0.3
0.3 |
0.9
0.9
0.9 |
16.0
17.0
18.5 |
17.0
18.0
19.5 |
150
240
240 |
0.3
0.3
0.3 |
0.9
1.35
1.35 |
20.5
28.0
28.5 |
21.5
32.0
32.5 |
300
360 |
0.3
0.3 |
1.35
1.35 |
31.0
34.0 |
35.0
38.0 |
| 0.65 |
6
12
22 |
0.3
0.3
0.3 |
0.9
0.9
0.9 |
7.0
9.0
11.0 |
8.0
10.0
12.0 |
24
33
40 |
0.3
0.3
0.3 |
0.9
0.9
0.9 |
11.0
13.0
13.5 |
12.0
14.0
14.5 |
|
| APPLIANCE HOOK-UP WIRE |
| UL/CSA |
SIZE |
RATING |
| 1007/TR-64 |
32-16 AWG |
80°C 300V |
| 1011/TR-32 |
28-16 |
80°C 300V |
| 1013/TR-32 |
28-9 |
90°C 600V |
| 1015/TEW |
28-9 |
105°C 600V |
| 1017 to 1023 |
22-2000 |
80°C 600V |
| 1024 to 1027 |
22-4/0 |
90°C 600V |
| 1028 |
22-8 |
105°C 600V |
| 1617 |
28-9 |
105°C 600V |
| 1618 |
32-16 |
80°C 300V |
| 2501 |
min. 30 |
105°C 600V |
|
APPLIANCE HOOK-UP WIRE
(CONT.) |
| UL/CSA |
SIZE |
RATING |
| 2502 |
min. 40
(2C or more) |
80°C 30V |
| 2532 |
min. 40
(2C or more) |
80°C 30V |
| 2570 |
30-9
(2C or more) |
80°C 600V |
| 2571 |
min. 30
(2C or more) |
80°C 600V |
| 2576 |
36-9 |
80°C 150V |
| 2969 |
min. 40
(2C or more) |
80°C 30V |
|
| TEFLON WIRE |
| UL |
SIZE |
RATING |
| 1180 |
26-16
AWG |
200°C 300V |
| 1199 |
26-16 |
200°C 600V |
| 1213 |
30-16 |
105°C |
| 1226 |
28-16 |
80°C |
| 1227 |
28-16 |
105°C |
| 1330 |
28-14 |
220°C 600V |
| 1331 |
28-16 |
150°C 600V |
| 1332 |
28-14 |
200°C 300V |
| 1333 |
28-16 |
150°C 300V |
| COAXIAL CABLE |
| UL/CSA |
SIZE |
RATING |
| 1071 |
30-16
AWG |
60°C 300V |
| 1107 |
30-16 |
60°C 300V |
| 1113 |
30-16 |
60°C 300V |
| 1354 |
min 40 |
60°C 300V
80°C |
| 1365 |
min 40 |
60°C 300V |
| 1489 |
min 40 |
60°C |
| 2674 |
30-16
(2~6C) |
60°C |
| 2791 |
min 40
(2~10C) |
80°C 300V |
| X'MAS TREE WIRE |
| UL/CSA |
SIZE |
RATING |
FXT
(W-A)/
TXF |
24-18
AWG |
60°C 125V |
| XT |
24-18
AWG |
60°C 125V |
| CXT* |
24-18
AWG |
60°C 125V |
| * The Max. Voltage is 300 for No. 18 AWG |
| TXFW |
8-16
AWG |
60°C 300V |
| CXWT |
18-16
14-12 |
60°C 300V |
| PXWT |
18-16 |
60°C 300V |
|
| FLAT RIBBON CABLE |
| UL/CSA |
SIZE |
RATING |
| 2468 |
32-6 AWG
(2C-150C) |
80°C 300V |
| 2569 |
28-16
(2C-12C) |
80°C 300V |
2824
SR-PVC |
32-16
(2C-150C) |
80°C 300V |
| 2084 |
24-20
(2C) |
80°C 300V |
| 2331 |
24-20
(2C-100C) |
80°C 300V |
| 2369 |
24-20
(2C) |
80°C 300V |
| POWER SUPPLY CORD |
| UL/CSA |
SIZE |
RATING |
| SPT-1/SPT-1 |
18AWG
(2C-3C) |
60°C 300V
105°C |
| SPT-2/SPT-2 |
18-16
(2C-3C) |
60°C 300V
105°C |
| STP-3/SPT-3 |
18-12
(2C-3C) |
60°C 300V
105°C |
20288
/SPT-1 |
18-12 |
105°C 300V |
CLOCK
CORD/PXT |
20(2C) |
60°C 125V |
SVT(W-A
shielded) |
18-17
(2C-3C) |
60°C 300V
105°C |
SJT(W-A
shielded) |
18-10
(2C-5C) |
60°C 300V
105°C |
ST(W-A
shielded) |
18-2
(2C-5C) |
60°C 600V
105°C |
SVTO(W-A
shielded) |
18-17
(2C-3C) |
60°C 300V
105°C |
SVTOO(W-
A shielded) |
18-17
(2C-3C) |
60°C 300V
105°C |
SJTO(W-A
shielded) |
18-10
(2C-5C) |
60°C 300V
105°C |
SJTOO(W-
A shielded) |
18-10
(2C-5C) |
60°C 300V
105°C |
STO(W-A
shielded) |
18-2 |
60°C 600V
105°C |
STOO(W-A
shielded) |
(2C-5C) |
60°C 600V
105°C |
| 2733 |
28-9
(2C-7C) |
105°C 600V |
Booster
Cable
(TPR/PVC) |
13-4 |
-70°C(TPR)
-34°C(PVC) |
|