INPUT
Voltage:

90 - 264 V AC

Frequency:

47 - 63 Hz.

 

Current:

<2 A

 

Inrush Current:
<45 A
Protection: fuse, thermal shutdown

 

Connector:
EN60 320 /C14/ 3Pin, Class I

EN60 320 /C18/ 2Pin,

Class II

OUTPUT
Voltage:

Rating table

Current:

Rating table

 

Regulation

< 5 %

Total Power

100 W Max

Noise & ripple

<1 %

Protection:

Short Ckt, OverLoad,Over

Volt

Hold up Time:

20mS min @120 VAC

Connector:

Out Plug/Cord Selection

GENERAL
Size:

142 x 76 x 43

±

1mm

Encl:

Black Plastic.

Marking:

Standard

Operating Temp:

-10 to +40 C

Storage Temp:

-20 to +85 C

Relative Humidity:
0% to 95%

non-condensing

Efficiency:

75 % typical

MTBF:

> 50,000 hours 

Approvals :

UL, CUL,TUV,CE

EMC:

FCC Level B, EN55022, EN55011 Class B

  1. Output Regulation (line/load): for single output units:

    ± 5%; for multiple output units:

    ± 5% for main output,

    ± 5% for second output and +10% for third output. (measured at the end of the output connector).

  2. 3.3 V units:
    Remote sensing is required to achieve specified output regulation.
  3. Output Ripple/noise (Peak-to-Peak):
    1% or 100 mV,whichever is smaller, except for +3.3V units whichis 50 mV maximum.
Options:

Remote Sensing: Provides regulation for main output within 2% of the nominal voltage. Single output units are available from 3.3 V up to 48.0 V in 0.1 V increments.

Custom output cords and connectors are available upon request.

Safety:

IEC950 models, UL 1950 to CSA 22.2 #950, EN60950
     IEC601 models, UL 601, C-UL to CSA 22.2 #601, EN60601.

CE Mark

Complies with EN5022, EN5011 Class B, and FCC part 15, Class B when tested with a resistive load, both conducted and radiated.
- Tested to comply with EN50082-1 including EN61000-4-2 EN61000-4-3, EN61000-4-4, EN61000-4-6, EN61000-4-11, EN61000-3-2 (PFC option).
Unit is eligible for CE Mark.