100 Watt Switching Power Supply General Specifications


INPUT
Voltage:
90 - 264 V AC
Frequency:
47 - 63 Hz.
 
Current:
<2 A
 
Inrush Current:
<45 A
Protection: fuse, thermal shutdown
 
Connector:
EN60 320 /C14/ 3Pin, Class I                        
EN60 320 /C18/ 2Pin, Class II                       
OUTPUT
Voltage:
Rating table
Current:
Rating table
 
Regulation
< 5 %
Total Power
100 W Max
Noise & ripple
<1 %
Protection:
Short Ckt, OverLoad,Over Volt
Hold up Time:
20mS min @120 VAC
Connector:
Out Plug/Cord Selection
GENERAL
Size:
142 x 76 x 43 ± 1mm
Encl:
Black Plastic.
Marking:
Standard
Operating Temp:
-10 to +40 C
Storage Temp:
-20 to +85 C
Relative Humidity:
0% to 95%
non-condensing
Efficiency:
75 % typical
MTBF:
> 50,000 hours 
Approvals :
UL, CUL,TUV,CE
EMC:
FCC Level B, EN55022, EN55011 Class B
  1. Output Regulation (line/load): for single output units:
    ± 5%; for multiple output units: ± 5% for main output, ± 5% for second output and + 10% for third output. (measured at the end of the output connector).
  2. 3.3 V units:
    Remote sensing is required to achieve specified output regulation.
  3. Output Ripple/noise (Peak-to-Peak):
    1% or 100 mV,whichever is smaller, except for +3.3V units whichis 50 mV maximum.
Options:

Remote Sensing: Provides regulation for main output within 2% of the nominal voltage. Single output units are available from 3.3 V up to 48.0 V in 0.1 V increments. Custom output cords and connectors are available upon request.

Safety:

IEC950 models, UL 1950 to CSA 22.2 #950, EN60950
     IEC601 models, UL 601, C-UL to CSA 22.2 #601, EN60601.

CE Mark

Complies with EN5022, EN5011 Class B, and FCC part 15, Class B when tested with a resistive load, both conducted and radiated.
- Tested to comply with EN50082-1 including EN61000-4-2 EN61000-4-3, EN61000-4-4, EN61000-4-6, EN61000-4-11, EN61000-3-2 (PFC option).
Unit is eligible for CE Mark.